Transducer installation in a blister
A recommended method for transducer installation is by using a blister. The blister must be
designed and manufactured by the installation shipyard to fit the transducer, as well as the
vessel’s size and hull shape. The transducer may be added to an already existing blister that
also holds other flush mounted transducers.
Illustration:
A
Blister
B
Mounting frame
C
Cable service loop
D
Transducer
E
Clamping frame
F
Screws
The best performance is obtained with
a blister height of 40 cm or more. A
streamlined shape and rounded edges
reduce the flow noise. A vertical leading
edge or front will guide the aerated water
to the sides of the blister.
The orientation of the blister should
follow the water flow.
The interior of the blister must be filled with sea water. Use drainage holes in the bottom and
an air outlet on the top. The water pressure behind the transducer will then compensate for
Summary of Contents for Simrad CP200-5C
Page 1: ...Photo by Gatis Marcinkevics kongsberg com simrad Simrad CP200 5C INSTALLATION MANUAL ...
Page 2: ......
Page 55: ...484164 A 53 Related topics Preparations page 22 Acoustic noise page 45 Preparations ...
Page 58: ...56 484164 A Related topics Preparations page 22 Simrad CP200 5C Installation Manual ...
Page 101: ...484164 A 99 Drawing file ...
Page 110: ... 2022 Kongsberg Maritime ...