Enclosure material ............................................................................................ Aluminium
Operating temperature range .................................................................. -15 °C to +55 °C
Recommended operating temperature .................................... Room temperature (+20 °C)
Storage temperature ................................................................................. -20 °C to +70 °C
Operating humidity ................................................................. Max. 95 % non-condensing
Storage humidity ........................................................................................ Less than 55 %
Ingress protection front ............................................................................................... IP 42
Ingress protection rear ................................................................................................ IP 21
2.4.3
Monitor, 17-inch LCD
Operating temperature range ............................................................................ 5 to +40 °C
Relative humidity .............................................................................................. 20 to 80 %
2.4.4
MRU Unit
Enclosure material ............................................................................. Anodised aluminium
Enclosure protection ................................................................................................... IP-66
Operating temperature range ........................................................................... -5 to +55 °C
Operating humidity (max) ......................................................................... Sealed, no limit
Storage temperature range ............................................................................. -20 to +70 °C
Storage humidity ....................................................................................... Sealed, no limit
Max allowed vibration operational (10 – 2000 Hz continuous) .............................0.5 m/s
2
Max allowed vibration non-operational (0 – 200 Hz continuous)...........................20 m/s
2
Max shock non-operational (10 ms peak) ...........................................................1000 m/s
2
2.4.5
GNSS antenna
Operating temperature range ................................................................... -40 °C to +85 °C
Ingress protection ..................................................................................... IP X6 and IP X7
3
Operating temperature up to +55 ºC for 10 hours.
Summary of Contents for Seapath 320
Page 1: ...Seapath 320 Technical Description ...
Page 22: ...Seapath 320 8 Man_techn_seapath320 rev 1 ...
Page 42: ...Seapath 320 28 Man_techn_seapath320 rev 1 ...
Page 50: ...Seapath 320 36 Man_techn_seapath320 rev 1 ...
Page 86: ...Seapath 320 72 Man_techn_seapath320 rev 1 6 1 Processing and HMI Units ...
Page 87: ...Technical Description Man_techn_seapath320 rev 1 73 ...
Page 88: ...Seapath 320 74 Man_techn_seapath320 rev 1 6 2 Antenna bracket ...
Page 89: ...Technical Description Man_techn_seapath320 rev 1 75 6 3 MRU and mounting bracket ...
Page 90: ...Seapath 320 76 Man_techn_seapath320 rev 1 ...
Page 91: ...Technical Description Man_techn_seapath320 rev 1 77 6 4 MRU junction box ...
Page 95: ...Technical Description Man_techn_seapath320 rev 1 81 6 7 6 U cabinet dimensions ...
Page 96: ...Seapath 320 82 Man_techn_seapath320 rev 1 ...