Note that an echo sounder can be designated as Master independent of which Trigger
mode is selected. Master can be set if the transmitting feedback signal is available and
is configured in the installation settings.
Note
The master setting is an advanced setting that only rarely is used (for example, EM 120
is the only KONGSBERG echo sounder that uses this setting). Also note that this setting
does not designate the echo sounder as "master". The K-Sync is always considered
the "master".
To quickly verify if any echo sounder is configured as master, see the
Echo Sounder
Status
area in the user interface. In figure
on page 52, the EM 120 is
configured as master. As with all the runtime settings, they are independently configured
for each user configuration profile.
In the figure
Trigger display for EA 600, EM 120 and SBP 120
on page 50 the EM 120
is set up as master and is triggered first (blue pulse). The other two echo sounders are
triggered once the EM 120 has transmitted (red pulse).
Figure 40
Trigger display for EA 600, EM 120 and SBP 120
Trigger display showing EM 120 (middle) configured as master. The EA 600 (top) and
the SBP 120 (bottom) do not get triggered until the EM 120 has transmitted.
Note
Maximize pinging will only be enabled for groups that does not have any echo sounders
in them designated as master. This ensures that all echo sounders ping at the same time,
but not while any echo sounder is receiving samples.