HiPAP Model 501/451/351/101
22
317748/F
5
SYSTEM UNITS
A HiPAP® system consists of the following main units:
Operator station
Transceiver unit
Hull unit with transducer and hoist control
Gate valve and mounting flange
Each transducer requires a dedicated hull unit arrangement and
transceiver unit. One operator station can control several
transceiver units.
5.1
Operator station
The HiPAP® system is operated from one or several operator
stations, depending on the actual system configuration. The
operator station is identical for all HiPAP® models. One station
can operate several HiPAP® transducers and of various types.
The Operator station comprises of:
Computer
Keyboard
Trackball
Display
The computer runs on the Microsoft Windows operating system.
The user interface is a graphical user interface, designed as a
standard Windows application.
A Keyboard and trackball is used to operate the system.
The screen is divided into 3 windows in which the operator can
select several different views. Typical views are graphical
position plot, numerical data, inclination and roll, pitch and
heading. A normal display configuration is shown in the
following figure.
One system may have one or several operator stations, which
communicates on an Ethernet. One of the operator stations will
be the Master. This is selected by the operator(s).