397152/E
27
7
Clean the threads in the transponder housing.
8
Feed the wires on the new connector through the connector hole.
9
Use Loctite 243 on the threads and apply activator.
10
Insert the connector.
11
Tighten the connector to 10 Nm.
12
Install the crimp terminals in the receptacle according to the cable drawing.
13
Put the battery and the PCB back in the tube.
14
Check and replace any damaged O-rings on the transducer before replacing it.
15
Connect the new connector and the transducer to the PCB.
16
Install the transducer.
Lubricating SEACON connectors
SEACON connectors require very little maintenance. They are designed to be used
in harsh environments and thus limited amounts of dirt and grit do not affect their
performance.
Context
It is recommended that, upon disconnecting or retrieving the system, the connectors be
cleaned, to storage (if possible, remate with dummy plugs). Prior to deployment the
following maintenance procedure is recommended:
Procedure
1
Demate the connector set.
Summary of Contents for cNODE MiniS
Page 1: ...397152 E September 2022 Kongsberg Maritime AS cNODE MiniS Transponder Instruction Manual ...
Page 6: ...6 397152 E cNODE MiniS ...
Page 37: ...397152 E 37 cNODE MiniS 3x 180 dimensions Drawing file ...
Page 38: ...38 397152 E cNODE MiniS 3x 40V dimensions cNODE MiniS Instruction Manual ...
Page 39: ...397152 E 39 cNODE MiniS 34 S dimensions Drawing file ...
Page 41: ...397152 E 41 Transducer guard dimensions Drawing file ...
Page 42: ...42 397152 E Floating collar dimensions cNODE MiniS Instruction Manual ...
Page 43: ...397152 E 43 TDR180 dimensions Drawing file ...
Page 44: ...44 397152 E TDR40V dimensions cNODE MiniS Instruction Manual ...
Page 45: ...397152 E 45 TDR30H dimensions Drawing file ...
Page 62: ... 2022 Kongsberg Maritime ...