24
436538/A
Charging the battery (on-deck)
Charging the battery is connected with some risk, please read the information and follow
the charge procedure carefully
Prerequisites
Caution
Equalise the temperature of the cNODE MiniS 1.11-50V Ti to between 10 °C and 40 °C
before charging it.
For on-deck charging, use the cNODE battery charger only.
Never charge the battery unattended.
Context
Always connect the cNODE battery charger to the cNODE MiniS 1.11-50V Ti before
connecting the cNODE battery charger to the mains (110 or 220 VAC).
The battery must be fully charged before long term storage and it is recommended to
recharge the battery every 6 months to make sure the battery does not discharge over time.
Required battery state for transportation is 30% or less remaining capacity to comply
with regulations.
Procedure
1
Switch off the cNODE transponder.
2
Let the unit warm up or cool down to an ambient temperature of 10 °C to 40 °C
before charging.
3
Connect the charger cable for cNODE MiniS 1.11–50V Ti to the transponder and
the charger.
4
Connect the charger to mains (110 or 220 VAC).
5
Remove the power cord after charging, before removing the connector to the
cNODE MiniS 1.11-50V Ti.
Result
The LED indicator on the charger flashes green when charging. It normally takes about
30 seconds before the charging starts and the LED indicator starts flashing green after
connecting the cNODE battery charger to the mains. The battery will be charged within
1 hour. The LED indicator will stay green when fully charged.
The transponder is then ready for use.
cNODE MiniS 1.11-50V Ti Instruction Manual