46
322217/G
5
Take out the battery, see the emergency procedure for opening a transponder with a
possible defect battery.
Opening a transponder with defect/possibly defect battery, page 45
Handling a transponder with an open relief
valve
Always read the emergency procedures before handling lithium batteries.
Procedure
1
Evacuate all unnecessary people.
2
Use a full face mask with minimum BE-filter, and protective equipment made of
rubber or plastic.
3
Fasten the transponder to a rope or a crane and immerse in the sea for 24 hours
or permanent. If this method is impossible, the unit can be cooled with copious
amounts of cold water using a fire hose.
4
Repeat this until no gases come out the relief valve and the temperature is low
and stable.
5
Take out the battery, see the emergency procedure for opening a transponder with a
possible defect battery.
Opening a transponder with defect/possibly defect battery, page 45
6
Wash out the residues from the chemical reaction with water.
Handling heated or warm batteries
Always read the emergency procedures before handling lithium batteries.
Procedure
1
Evacuate all unnecessary people.
2
Fasten the battery to a rope or a crane and immerse in the sea for 24 hours or
permanent. If this method is impossible, the unit can be cooled with copious
amounts of cold water using a fire hose.
3
Wash out the residues from the chemical reaction with water.
Kongsberg cNODE Instruction Manual
Summary of Contents for cNODE Maxi
Page 1: ...Instruction Manual cNODE Maxi and Midi Transponders Medium Frequency 4000 metres ...
Page 2: ......
Page 69: ...322217 G 67 Differential inclinometer arrangement drawing About drawings ...
Page 70: ...68 322217 G Current meter arrangement drawing Kongsberg cNODE Instruction Manual ...
Page 98: ... 2019 Kongsberg Maritime ...