9
Gas Connection and Safety
1.
For LPG (cylinder) connection, affix
metal clamp on the hose coming from LPG
cylinder. Affix an edge of the hose on hose
inlet connector behind the appliance by
pushing to end through heating the hose
in boiled water. Afterward, bring the clamp
towards end section of the hose and tighten
it with screwdriver. The gasket and hose
inlet connector required for connection is
as the picture shown below.
NOTE:
The regulator to be affixed on LPG cylinder should have 300
mmSS feature.
2.
Natural gas connection should be
done by authorized service. For natural
gas connection, place gasket in the nut
at the edge of natural gas connection
hose. To install the hose on main gas
pipe, turn the nut. Complete the con-
nection by making gas leakage control.
Gas hose and electric connection of the appliance should
not pass next to hot areas such as back of the appliance.
Gas hose should be connected by making wide angle turns
against breaking possibility. Movement of appliance whose
gas connection is made may cause gas leakage.
Main Gas Pipe
Gasket
Hose Inlet Connector
Metal Clamp
Lpg Connection Hose
Main Gas Pipe
Gasket
Nut
Natural Gas Connection Hose
True
False
True
True
GB