EN - 50 -
Warnings about temperature adjustments
•
It is not recommended that you operate your fridge in environments colder than 10°C in
terms of its efficiency.
•
Temperature adjustments should be made according to the frequency of door openings
and the quantity of food kept inside the fridge.
•
Your fridge should be operated up to 24 hours according to the ambient temperature
without interruption after being plugged in to be completely cooled. Do not open doors
of your fridge frequently and do not place much food inside it in this period.
•
A 5 minute delaying function is applied to prevent damage to the compressor of your
fridge, when you take the plug out and then plug it in again to operate it or when an
energy breakdown occurs. Your fridge will start to operate normally after 5 minutes.
•
Your fridge is designed to operate in the ambient temperature intervals stated in the
standards, according to the climate class stated in the information label. We do not
recommend operating your fridge out of stated temperatures value limits in terms of
cooling effectiveness.
•
This appliance is designed for use at an ambient temperature within the 16°C - 38°C
range.
Climate class and meaning:
T (tropical):
This refrigerating appliance is intended to be used at ambient temperatures
ranging from 16 °C to 43 °C.
ST (subtropical):
This refrigerating appliance is intended to be used at ambient
temperatures ranging from 16 °C to 38 °C.
N (temperate):
This refrigerating appliance is intended to be used at ambient temperatures
ranging from 16 °C to 32 °C.
SN (extended temperate):
This refrigerating appliance is intended to be used at ambient
temperatures ranging from 10 °C to 32 °C.
Climate class
Ambient temperature (
o
C)
T
Between 16 and 43
o
C
ST
Between 16 and 38
o
C
N
Between 16 and 32
o
C
SN
Between 10 and 32
o
C
Summary of Contents for UHC1A54251DVN
Page 1: ...UHC1A54251SVN UHC1A54251DVN...
Page 2: ......
Page 23: ...MK 21 22 22 26 26 27 28 28 28 28 30 30 30 31 31 32 36 36 37 38 38 39 40 41 42 42 42...
Page 24: ...MK 22 1 R600...
Page 25: ...MK 23...
Page 26: ...MK 24 16 8 3 8 0 3 3 8 8 14 2000 m...
Page 27: ...MK 25...
Page 28: ...MK 26 CFC...
Page 29: ...MK 27 220 240 50 50 5 2...
Page 30: ...MK 28 2 1 5 3 1 1 2 3 4 5 10 C 24...
Page 31: ...MK 29 5 5 16 C 43 C ST 16 C 38 C N 16 C 32 C SN 10 C 32 C...
Page 32: ...MK 30...
Page 33: ...MK 31 4 C 0 8 C 0 8 C 3...
Page 34: ...MK 32 1 2 3 3 4 1 1 24 3...
Page 35: ...MK 33 6 8 6 8 6 8 6 8 4 8 1 3 1 3 4 6 4 6 2 5 6 8 2 4 2 4 4 6 2 3 3...
Page 36: ...MK 34 10 13 12 6 8 12 8 10 6 9 10 12 2 cm 10 12 12 8 10 4 6 8 12 10 12 8 12...
Page 38: ...MK 36 4...
Page 39: ...MK 37 5 1 2 A 3 15 W B 4 C...
Page 40: ...MK 38 5 6...
Page 41: ...MK 39 1 2 3 4 5 6 7...
Page 42: ...MK 40 7 10 11 3 4 5 6 7 B 8 9 A 2750 2 1 12 B 1 2 3 4 5 6 7 8 9 10 11 12...
Page 63: ...EN 61...
Page 66: ......
Page 67: ......