background image

 

18

 

Use 

The hood is designed to be used either for exhausting or filter 
version. 
  

 Ducting version

 

In this case the fumes are conveyed outside of the building by 

means of a special pipe connected with the connection ring 
located on top of the hood. 

Attention

! The exhausting pipe is not supplied and must be 

purchased apart. 
Diameter of the exhausting pipe must be equal to that of the 
connection ring. 
In the horizontal runs the exhausting pipe must be slightly 
slanted (about 10°) and directed upwards to vent the air easily 

from the room to the outside. 
Attention! If the hood is supplied with active charcoal filter, 
then it must be removed. 

Connect the hood and discharge holes on the walls with a 
diameter equivalent to the air outlet (connection flange). 

Use a duct of the minimum indispensible length. 

Use a duct with as few elbows as possible (maximum 
elbow angle: 90°). 

Avoid drastic changes in the duct cross-section. 

Use a duct as smooth as possible inside. 

The duct must be made of certified material. 

Attention! If the hood is supplied with carbon filter, then it 
must be removed. 

  

 Filter version

 

One active charcoal filter is needed for this and can be 
obtained from your usual retailer.  
The filter removes the grease and smells from the extracted 
air before sending it back into the room through the upper 
outlet grid. 

Attention! If the hood is not supplied with carbon filter, 
then it must be ordered and mounted. 

 

Installation 

The minimum distance between the supporting surface for the 
cooking equipment on the hob and the lowest part of the 
range hood must be not less than 50cm from electric cookers 
and 65cm from gas or mixed cookers. 
If the instructions for installation for the gas hob specify a 
greater distance, this must be adhered to. 

 

  Electrical connection 

The mains power supply must correspond to the rating 
indicated on the plate situated inside the hood. If provided with 
a plug connect the hood to a socket in compliance with current 
regulations and positioned in an accessible area, after 
installation. If it not fitted with a plug (direct mains connection) 
or if the plug is not located in an accessible area, after 
installation,  apply a double pole switch in accordance with 

standards which assures the complete disconnection of the 
mains under conditions relating to over-current category III, in 
accordance with installation instructions. 

Warning!

 Before re-connecting the hood circuit to the mains 

supply and checking the efficient function, always check that 
the mains cable is correctly assembled. 
The hood is provided with a special power cable ; if the cable 
is damaged, request a new one from Technical Service. 

 

Mounting 

Before beginning installation: 

 

• 

Check that the product purchased is of a suitable size for 
the chosen installation area. 

•  Remove the charcoal (*) filter/s if supplied (see also 

relative paragraph). This/these is/are to be mounted only 

if you want lo use the hood in the filtering version. 

•  Check (for transport reasons) that there is no other 

supplied material inside the hood (e.g. packets with 
screws (*), guarantees (*), etc.), eventually removing 

them and keeping them. 

• 

If possible, disconnect and move freestanding or slide-in 
range from cabinet opening to provide easier access to 
rear wall/ceiling. Otherwise put a thick, protective 

covering over countertop, cooktop or range to protect 
from damage and debris. Select a flat surface for 
assembling the unit. Cover that surface with a protective 
covering and place all canopy hood parts and hardware 
in it. 

• 

In addition check whether near the installation area of the 
hood (in the area accessible also with the hood mounted) 
an electric socket is available and it is possible to 

connect a fumes discharge device to the outside (only 
suction version).  

•  Carry out all the masonry work necessary (e.g. 

installation of an electric socket and/or a hole for the 
passage of the discharge tube). 

  
This hood is designed for fitting in a cabinet or on some other 
support. 

 

Summary of Contents for NBI 50B

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ...pogon ili na drugo gorivo Zrak koji se usisava ne smije biti proveden u cijev koja se koristi za izbacivanje dimova koje proizvode ostali aparati na plinski pogon ili drugo gorivo Strogo se zabranjuje...

Page 16: ...u s jednim utika em koja je u skladu s propisima na snazi i koji je postavljen na pristupa nom mjestu ak i nakon instalacije Ako nije opremljen utika em direktno povezivanje s mre om ili utika nije po...

Page 17: ...1 Zadr ava estice masno e koje se stvaraju prilikom kuhanja Taj filtar morate istiti jednom mjese no upotrijebiv i neagresivne deterd ente bilo ru no ili u stroju za pranje posu a u kojem slu aju mora...

Page 18: ...of foods beneath the hood itself is severely prohibited The use of exposed flames is detrimental to the filters and may cause a fire risk and must therefore be avoided in all circumstances Any frying...

Page 19: ...he hood If provided with a plug connect the hood to a socket in compliance with current regulations and positioned in an accessible area after installation If it not fitted with a plug direct mains co...

Page 20: ...declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations Grease filter Fig 10 21 Traps coo...

Page 21: ......

Reviews: