background image

12

•GM672-UC

1

2

4

5

6

7

8

9

10

11

12

13

14

15

17

18

19

20

21

22

23

24

25

26

27

28

30

32

33

34

16

3

31

29

2 Names of parts and list of main parts

Summary of Contents for Solar Assault

Page 1: ......

Page 2: ...get started immediately turn OFF the power switch and contact your nearest dealer This manual covers the following models GN672 UC GM672 UC The specifications of GN672 UC may be somewhat different fro...

Page 3: ...me environment manual test 19 5 3 Mode descriptions 20 6 Setting up the game machine 6 1 Connecting the unit GN672 UC only 24 6 2 Fastening the adjusters 25 6 3 AC bracket 26 6 4 Service panel 27 6 5...

Page 4: ...used when the product is used improperly with the suggestions disregarded The following graphic suggestions describe the types of precautions to be followed Indicates a matter of which care should be...

Page 5: ...eath or serious injury Do not set up the game machine In a place exposed to rain or moisture In a place exposed to direct sunlight In a place exposed to direct heat from air conditioning and heating e...

Page 6: ...so may result in electric shock or trouble Clearances of 100 mm 3 94in or more should be created between the game machine and walls CAUTION Operation 4 WARNING Precautions for use If there is any abno...

Page 7: ...pact to the machine either The thing may drop or the machine get damaged which may get you injured CAUTION Be sure to turn OFF the power switch and unplug the power cord from the receptacle before ins...

Page 8: ...apply undue force to the connections of the cockpit GN672 UC Application of undue force may cause injury accident or damage of the machine When moving the machine use care not to apply undue force to...

Page 9: ...7 MEMO...

Page 10: ...nual Keys for coin door 2 Keys for maintenance 2 Spare fuse 10A 1 Unit connecting pipe 1 Unit connecting pipe fixing screw M4 x 10L 4 M4 x 20L 4 Grounding wire 1 Projector adjusting remote controller...

Page 11: ...r monitor Temperature 10 to 35 C 50 to 95 F Humidity 20 to 80 No dewing is allowed Instruction manual This manual Keys for coin door 2 Keys for maintenance 2 Spare fuse 10A 1 Grounding wire 1 If any p...

Page 12: ...10 2 Names of parts and list of main parts GN672 UC 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 28 29...

Page 13: ...ng power Game PC board Speaker Super woofer POWER UP button VIEW SHIFT button Unit connecting pipe Transformer 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 12 10 1 1 1 2 1 1 1 1 1 Part Quanti...

Page 14: ...12 GM672 UC 1 2 4 5 6 7 8 9 10 11 12 13 14 15 17 18 19 20 21 22 23 24 25 26 27 28 30 32 33 34 16 3 31 29 2 Names of parts and list of main parts...

Page 15: ...Caster Adjuster Switching power Switching power Game PC board POWER UP button VIEW SHIFT button Transformer 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 3 1 1 1 1 1 1 8 6 1 1 1 1 1 1 Part Quantity Remarks No...

Page 16: ...sly with the missile button If both the buttons are pressed at once you can fire the sharpshooting laser gun Fighter for advanced level players Missile Fired in front downward direction from the mainf...

Page 17: ...to GAME OPTIONS on page 23 Types of power up The types of basic power up are as shown below They vary depending on the type of fighter See page 14 Missile Enables you to use a missile which can be re...

Page 18: ...ey into the keyhole of the door in the upper portion of the coin door unit and turn it clockwise How to close the maintenance door Take care not to apply any load or impact to the maintenance door whe...

Page 19: ...r and turn it clockwise 2 Open the coin door and take out the coin box Coin counter You will find the coin box when the coin door is opened The coin counter is located under the coin box Securely lock...

Page 20: ...the demonstration game gets started If test is OK BAD appears on the screen and the checking is repeated If 24G BAD is displayed once turn OFF the power switch and then turn it ON again while depressi...

Page 21: ...basic items Selecting each mode How to select each mode from the main menu SELECT Press the VIEW SHIFT button or POWER UP button SET Pull the trigger After selecting a mode refer to the page on which...

Page 22: ...ODIFICATION will appear and the modified settings will not be saved When FACTORY SETTINGS is selected and the trigger is pulled all the settings return to the factory settings MEMO I O CHECK Checking...

Page 23: ...he screen display Adjust the focus distortion and size of the image on the screen while watching the crosshatch pattern according to Adjusting the projector See page 42 and monitor See page 44 To retu...

Page 24: ...es is turning MAIN TRIGGER OR MISSILE EXIT C G BOARD CHECK SOUND OPTIONS Turns on and off the demo play sound ALL THE TIME Sound always on ONCE EVERY 4 CYCLES Sound on every 4 cycles COMPLETE OFF Soun...

Page 25: ...the position where Continue is set ALL STAGE Game is resumed from the first part of the last stage where Continue is set LAST STAGE ONLY Game is resumed from the first part of the last stage only when...

Page 26: ...hose of the unit connecting pipe 2 Attach the connector cover with the accompanying screws Do not move the units by pulling bundled wires connectors or unit connecting pipes which come out of the cock...

Page 27: ...adjusters 6 adjusters for GM672 UC on the floor make sure that the machine is installed stable at level and then tighten the hexagonal nuts upward GN672 UC GM672 UC Maximum adjusting height 80mm Min 6...

Page 28: ...telephone ground terminal 6 Setting up the game machine GN672 UC There is an AC bracket at the front of the cockpit unit GM672 UC There is an AC bracket at the back of the main unit Grounding wire Gro...

Page 29: ...ntenance door is opened with the attached maintenance key 6 Setting up the game machine GN672 UC GM672 UC Service panel Service switch Test switch Coin counter compartment Service panel Coin counter c...

Page 30: ...it and the projector unit beforehand Do not apply undue force while moving the units When connecting the separated units take care not to catch the wiring and your hand between the units The machine c...

Page 31: ...the wiring and your hand between the units The machine can be divided into the units 1 Remove the screws off the joint fitting A at the side of the seat unit 2 Remove the screws off the joint fitting...

Page 32: ...ch and unplug the power cord from the receptacle before moving the coin counter 1 Remove the front door of the cockpit unit 2 Disconnect the coin counter connector 3 Open the coin door remove the coin...

Page 33: ...n unplugged Never touch those parts When closing the back door be sure to secure it with the two screws 1 Remove the back door 2 Disconnect the coin counter connector 3 Open the coin door remove the c...

Page 34: ...32 MEMO...

Page 35: ...ance and annex 7 2 Replacing the fuse How to replace the fuse 10A 1 pc Before replacing the fuse be sure to turn OFF the power switch and unplug the power cord from the receptacle Be sure to replace t...

Page 36: ...ke care not to damage the wiring connecting the fluorescent light unit and the game machine 1 Remove the fluorescent light unit lock screws off the top of the billboard 2 Lift the fluorescent light un...

Page 37: ...it with a new one of the same type straight tube 20W 100V 1 Remove the cover off the back of the billboard 2 Push one end of the fluorescent light in the direction of the socket The other end of the f...

Page 38: ...t of the control lever unit 1 Peel off the sticker of the control sheet up to the slit and remove the control sheet from the control lever 2 Remove the screws and then the control cover and the plate...

Page 39: ...the connector from the control lever GN672 UC GM672 UC 4 Remove the screws and then the control lever unit GN672 UC GM672 UC Control lever unit Screw 5 Reassemble the control lever unit in the revers...

Page 40: ...e power cord from the receptacle 7 Maintenance and annex 1 Remove the screws and then the side cover 2 Remove the screws and then the socket lock bands 3 Pull out the socket MEMO It is recommended to...

Page 41: ...ttention to the direction of the micro switch see page 38 Be careful not to confuse the wires Be sure to reconnect the wires to the COM and NO terminals of the new socket micro switch 7 Maintenance an...

Page 42: ...contrast Brightness adjustment Used to change the brightness Turning it clockwise will make the image brighter Horizontal screen position adjustment Used to change the raster position in the horizont...

Page 43: ...the status before adjustment is performed When the screen is disturbed by static electricity etc during the adjustment of the unit turn OFF the power switch and on again and readjust the unit If the...

Page 44: ...ter of the yellow cross When the blue cross is superimposed on the yellow cross the resultant cross looks white MEMO Selecting red again after adjusting blue will make the red disappear so select a se...

Page 45: ...pears on the screen along with the green test pattern and the green marker turns red 5 Press the POSITION keys on the remote controller to move the marker to the place you want to adjust The range whe...

Page 46: ...ockwise will make the red deeper Green input gain adjustment Changes green brightness Turning it clockwise will make the green deeper Blue input gain adjustment Changes blue brightness Turning it cloc...

Page 47: ......

Reviews: