Trouble Shooting:
Technical Specifications:
15
Model #
Kegerator does not turn on
Dimensions (W x D x H)
Kegerator does not seem cold enough
Net Volume Total (cu ft/L)
Kegerator shuts off/on too often
Refrigerant Type
Product Weight Max (lbs/kg)
Kegerator seems to make too
much noise
Error Code On Temperature Display
Control Type
Rated Voltage Frequency
Ambient temperature
Cooling System
Input Power
Temperature Range
Light
Current
ND-1600
With Stainless Steel Top Cover: 23.85" x 24.9" x 35.43"
Without Stainless Steel Top Cover : 23.85" x 24.86" x 34.375"
Check temperature setting by placing cup of water with a
thermometer inside fridge. Check after 2 hours & compare
against set kegerator temperature. Kegerator may need to
cool longer or the door gasket may not be sealing correctly.
6.6cu ft/187L
Check to see if the door gasket is sealing correctly. Or the
ambient room temperature is too high so the unit is working
harder to cool to set temperature
104lbs/47.5kg
Humming is normal. Gurgling sounds are caused by cooling
liquid used by the kegerator. Or unit may not be not level.
E0: Defrost sensor malfunctions.
E1: Cabinet inner temperature sensor malfunctions.
E2: Short circuit of the sensors or thermostat control board.
Digital Touch Pad
32°F–104°F/0°C–40°C
R600a
115v/60Hz
130W
1.6A
Auto Defrost
28.4°F–76°F/-2°C–24°C
LED Interior Light
Check circuit breaker, fuse and check plugs.
Distributed By Brewmaster
™
Still have issues? Call customer service at 1–800–600–0033
CAUTION
• If the unit loses power (unplugged, moved, turned off) you will need to wait 3 minutes before restarting otherwise the unit may
not properly turn on and you can cause damage to the compressor.
• When turning on for the first time, or after being off for a few days, the temperature read-out will be off by a few degrees for 3–4
hours. Once the temperature normalizes it will read correctly.