background image

  Let the KRYO sit for at least 24 hours after delivery or after sitting on its side before turning the unit on.

  Whenever the KRYO is operating and cooling the reservoir, the agitator pump needs to be operating to keep the liquid 

in the reservoir agitated and avoid ice formation. The pump is wired into the temperature controller and hence should 

always be running when the unit is turned on.

Assemble The Sight Tube:

Firmly push the two 3/8" Duotight tee pieces (

DUO109

) onto the push fit tubes on the front of the KRYO and push 

your sight tube into each of the Duotight tee pieces as shown on the diagram on Page 5. Confirm this is held in place 

securely by pulling on the Duotight fittings and ensuring they are locked in place. Then, push a 3/8" plug (

DUO119

into each of the Duotight tee pieces.
To remove the plug/tube from the Duotight tee piece, push the collar on the tee piece in towards the fitting as you pull 

the plug/tube out of the tee piece.

Attaching A Keg:

1.  On the back side of the KRYO you will find two 5/8" threaded shanks. Screw a Duotight Beer Thread Adapter 

(

DUO104

) onto each of the threaded shanks (ensuring the washer is in place internally on the Duotight).

2.  Push 8mm OD EVABarrier hose into the Duotight fitting on the shank on the back side of the KRYO.
3.  Connect this 8mm OD EVABarrier hose to your coupler or disconnect on your keg.

LEAK TESTING PRODUCT LINES

It is essential to pressure test both product lines prior to running any liquid through them for dispensing.
The product lines need to be pressure tested to a pressure that is at least 1.5 times the pressure that will be used for 

dispensing to a maximum of 50 psi. For example, if your dispensing pressure is 20 psi then your product lines should 

be pressure tested at 30 psi and your testing pressure shouldn’t exceed 50 psi.
The product lines can be leak tested via multiple methods which are outlined below. It is a good idea to test the system 

using multiple methods to be certain the system is holding pressure:

PRESSURE DECAY TEST: 

1.  Screw a Duotight Beer Thread Adapter onto each all thread shank on the side of the KRYO.
2.  Push 8mm EVABarrier hosing connected to a regulated pressure source into one of the Duotight fittings.
3.  Set the pressure on the regulator to 1.5 times the dispensing pressure up to a maximum of 50 psi.
4.  Turn the gas cylinder off and leave to sit for a few hours. Then check if the pressure on the regulator has decreased 

from the set pressure.

If the pressure has dropped, double check that the leak isn’t occurring externally from the KRYO. Check all Duotight 

connections and connections to your gas cylinder or regulator with a soapy solution to check for the formation of 

bubbles indicating a leak.
If the pressure remains stable then this product line has passed the leak test.
Perform the above steps on the other product line.

AIR-LEAK TEST: 

1.  Fill the reservoir with water.
2.  Screw a Duotight Beer Thread Adapter onto each all thread shank on the side of the KRYO.

INITIAL START-UP & TESTING

2

Summary of Contents for KRYO

Page 1: ...amage and will void the product warranty GENERAL PRECAUTIONS If the KRYO has just been moved do not turn on unless the KRYO has been standing upright for 24 hours Failure to do so will void warranty S...

Page 2: ...ssure test both product lines prior to running any liquid through them for dispensing The product lines need to be pressure tested to a pressure that is at least 1 5 times the pressure that will be us...

Page 3: ...2 hours to ensure that it drops the temperature of the reservoir to the set temperature on the temperature controller The system has now been tested for cooling and leaks and is ready to be used to di...

Page 4: ...18 F 7 8 C 1 015 30 8 F 13 3 C 1 024 You can measure the glycol percentage using a calibrated refractometer and comparing to the specific gravity at 32 F in the above table We would advise running a 2...

Page 5: ...DISPENSING FROM COMMERCIAL KEGS Faucets Duotight to Female Beer Thread Fttings CO 2 Tank Tap Handles Duotight 8mm Tee Sanke Coupler Sanke Keg Sanke Keg Sanke Coupler 5 5...

Page 6: ...Ball Lock QD Gas In Flare Duotight 8mm Flare Duotight 8mm Flare Ball Lock QD Bev Out Flare Duotight 8mm Flare Duotight 8mm Tee Ball Lock QD Bev Out Flare CO 2 Regulator Faucets Tap Handles Duotight t...

Page 7: ...e a specific carbonation level during carbonation or priming refer to the table below and correlate the temperature of the keg with the desired carbonation level NOTE Do not try to fix a slow or fast...

Page 8: ...10 9 12 2 13 5 14 8 16 1 17 3 18 6 19 9 21 2 22 5 23 8 25 1 26 4 27 6 28 9 30 2 31 5 32 8 34 0 35 3 36 6 37 9 39 1 40 4 41 7 42 9 44 2 54 11 6 4 7 7 9 1 10 4 11 8 13 1 14 4 15 7 17 1 18 4 19 7 21 1 2...

Page 9: ...the beverage you re dispensing THE CONTROLLER UNIT ITSELF IS FAIRLY STRAIGHTFORWARD BUT IT S STILL A GOOD IDEA TO GET FAMILIAR WITH THE BUTTONS FUNCTIONS THE DESIRED TEMPERATURE SETTING THE TEMPERATU...

Reviews: