17
Air handling unit transportation by forklift truck or hand pallet truck
2 a Picture
2 b Picture
2 a Unit is transported by hand pallet truck on a wooden pallet;
2 b Unit is transported by forklift truck on a wooden pallet.
The unit should be examined upon receipt, to ensure that no visible damage has occurred during transit,
and the advice note checked to ensure that all items have been received. If damage or delivery shortages are
discovered, the carrier should be immediately informed. AMALVA should be notified within three days of receipt,
with a written confirmation sent within seven days. AMALVA can accept no responsibility for damage by unloading
from carrier or for subsequent damage on site.
If the unit is not to be installed immediately, it should be stored in a clean, dry area. If stored externally, it should
be adequately protected from the weather.
BRIEF DESCRIPTION OF THE UNIT
•
The air handling units are intended for ventilation of small and medium-sized spaces (eg. single family houses,
offices, etc.), having operating ambient temperature and relative humidity. The unit is intended to be installed
in the kitchen or other domestic premises. Mineral wool is used for thermal insulation and sound attenuation.
Units cover panels are 25 mm thick. As standard, the unit is designed for indoor placement. In cold, wet rooms
possible icing or condensation on the housing inside and outside. The operating temperature range for the unit
is -30 °C ... 40 °C, outdoor air temperature. The air handling unit is not to be used to transport solid particles,
even not in areas where there is a risk of explosive gases. Extracted indoor air tempe10 – +40 °C,
relative humidity (non-condensing) 20–80 %.
• DOMEKT RECU 300/450VE(W)-B (3 Picture) series units are equipped with a plate heat exchanger, air filters,
an electric air heater, fans and automation control system, to ensure safe and efficient operation of the unit.
•
Before you open the door, the unit must be switched off and the fans must have been given time to stop (up
to 3 min.).
•
The unit contains heating elements that must not be touched when they are hot.
• We recommend to leave air handling unit in working mode (minimum 20 percent of power) during the first
operation year. Due to moisture in building constructions, condensation may occur inside and outside the air
handling unit. Continuous operation of the equipment will significantly reduce the risk of condensation.
•
To maintain a good indoor climate, comply with regulations and, to avoid condensation damage, the unit must
never be stopped apart from during service/maintenance or in connection with an accident.
•
If the unit is placed in spaces with high humidity, condensation might occur on the surface of the unit when
outdoor temperatures are very low..