To activate ventilation by a weekly schedule
1
:
1. Press “Menu” button at the bottom of the home screen.
2. Press “Planning” button in the menu window.
3. Use the arrows at the bottom of the window to select a desired weekly schedule.
4. Press a return icon at the top of the window twice to return to the home screen.
5. Press AUTO button to activate scheduled ventilation.
6. Information about upcoming changes in the schedule is displayed at the top of the screen.
Overview
Scheduling
TURN OFF
Settings
Menu
Scheduling
WORKING WEEK
0 4 8 12 16 20 24
Mo
Tu
We
Th
Fr
Sa
Su
16:30
INTENSIVE
ECO
АUTO
AWAY 18:00
Next
3.1.5. Air quantity and temperature settings
You can set air flow for supply and exhaust air, desired
temperature and turn off/on an electric heater for each ven-
tilation mode. If turned off, the heater will not turn on even
when the desired temperature is not reached. If turned on,
the heater will operate only when a heat exchanger alone
cannot reach the set temperature.
To change the ventilation mode settings:
1. Press an icon indicating the current operation mode
in the middle of the home screen.
2. Press a desired mode button and hold it for 5
seconds.
3. Press a parameter you want to change.
4. Use the arrows to select a desired value and press to confirm.
5. Press a return icon at the top of the screen to return to the home screen.
Tiekiamas srautas
210 m3/h
Šalinamas srautas
210 m3/h
Elektrinis šildytuvas
Įjungta
Oro temperatūra
20,0 °C
INTENSIVE
Reset settings
21,0
5,0 °C
40,0 °C
Air temperature
Tiekiamas srautas
210 m3/h
Šalinamas srautas
210 m3/h
Elektrinis šildytuvas
Įjungta
Oro temperatūra
20,0 °C
INTENSIVE
Reset settings
20
20 %
100 %
Supply flow
INTENSIVE
Reset settings
Electric heater
Off
On
1
Ventilation by a weekly schedule is not possible when air quality control function is activated.
INTENSIVE
NORMAL
AWAY
BOOST
HOLIDAYS
KITCHEN
OVERRIDE
FIREPLACE
Operation modes
5 s
Supply flow
70 %
Extract flow
70 %
Electric heater
On
Air temperature
20,0 °C
INTENSIVE
Reset settings