background image

11

10

Function 

Directions 

ALTI 

This feature provides an altitude correction to the CO

2

 level for increased accura-

cy. Select this feature, then use UP and DOWN to input the current altitude (look it 

up if unknown) in meters. Press ENTER once altitude is correct. 

ºC/ºF 

Use this feature to toggle between Celsius and Fahrenheit for the temperature 

display. First use UP and DOWN, then ENTER when the desired one is selected. 

ADV 

This function toggles between 4 things when selected: changing the alarm and 

lights to suit levels For Low border, or For Hi border, or change the dataloginterval, 

or Restore factory setting. Restore factory setting will reset the device to factory 

settings and erase all stored data in the chart. To use any of these modes, hold 

ENTER for 3 seconds until an audible beep.

(Return) 

Exits the main menu. No options will be displayed on the green bar. A different 

audible beep be heard in this option. 

6. Specifications 

Typical test conditions, unless otherwise specified: Ambient Temp =23+/-3°C, RH=50%-70%, 

 

Altitude=0~100 meter

Measurement 

Spec 

Operating Temperature:

32°F bis 122°F (0°C bis 50°C) 

Storage Temperature:

-4°F bis 140°F (-20°C bis 60°C) 

Operating & Storage RH: 

0-95%, non-condensing 

CO

2

 Measurement  

Measurement Range:

0-5000ppm 

Display Resolution: 

1ppm (0-1000); 5ppm (1000-2000); 10ppm (>2000) 

Response Time / Warm-up Time: 

<30 sec 

Temp. Measurement 

Operating Temperature:

32°F bis 122°F (0°C bis -50°C) 

Display Resolution:

0.1°F (0.1°C) 

Response Time:

<20min (63%) 

RH Measurement  

Range: 

5-95% 

Resolution:

1%

Power Requirements: 

160mA Peak, 15mA average bei 5.0V 

Input: 115VAC 60Hz, or 230VAC 50Hz, 0.2A

Output: 5VDC 5.0W max.

Average active efficiency: 73.77%

Noload power consumption: 0.075W

Dimension: 

4.7x2.6x1.3inch (120x66x33mm) 

Weight: 

103g only instrument without power supply

7. Rear View:

8. Disclaimers: 

USB connection is for power supply only; no communication with PC. Unplugging the device may 

result in loss of most recent logged data on the chart. 

This device is not intended for workplace hazard CO

2

 monitoring, nor intended as a definitive monitor 

for human or animal health institutions, life sustenance, or any medical-related situation. 

We and the manufacturer assumes no responsibility for any damage or loss suffered by the user or 

any third party arising through the use of this product or its malfunction. 

We reserve the right to change the spec without notice. 

Note (in case of Accu use): 

Recommend Accu (Powerbank): larger or equal to 4000mAh (3000mAh still works, with reduced battery life) 

Recommend battery size: smaller than 101x60x22mm / 4.0x2.4x0.87inch,larger battery still works, but 

not easy to fit in.

10. Waste disposal

This product has been manufactured using high-grade materials and components which can be recycled and 

reused 

Never dispose of empty batteries and rechargeable batteries in household waste.

As a consumer, you are legally required to take them to your retail store or to an appropriate coll-

ection site depending on national or local regulations in order to protect the environment. 

The symbols for the heavy metals contained are: Cd=cadmium, Hg=mercury, Pb=lead

This instrument is labelled in accordance with the EU Waste Electrical and Electronic Equipment 

Directive (WEEE). Please do not dispose of this instrument in household waste. The user is 

obligated to take end-of-life devices to a designated collection point for the disposal of electrical 

and electronic equipment, in order to ensure environmentally-compatible disposal. 

9. Explanation of symbols  

This sign certifies that the product meets the requirements of the EEC directive and has been 

tested according to the specified test methods.

Summary of Contents for Air Co2ntrol 5000

Page 1: ... 0111 www dostmann electronic de Bedienungsanleitung 2 Operating Instruction 7 CO2 Monitor mit Datenloggerfunktion Micro SD Karte CO2 Monitor with Data logger function Micro SD card KOMETEC Karl Oelkers e K Mess und Prüfgeräte Shop Mozartstr 10 D 88097 Eriskirch T 07541 955 1313 F 07541 955 1131 info kometec de www kometec de ...

Page 2: ...Micro USB Kabel Bedienungsanleitung Netzteil für USB Kabel Micro SD Karte 4 Funktionen im Überblick CO2 Anzeige Bargraphanzeige für den Verlauf Variable Zoomfunktion für Bargraph 2 Kanal NDIR Sensor Daten Logger Funktion via SD Karte Echtzeituhr 3 Farben LED Ampel 5 Bedienung des Gerätes Inbetriebnahme Nach dem Auspacken das Gerät mit Netzteil via USB Kabel verbinden Sobald die richtige Spannung a...

Page 3: ... Intervall kann individuell eingestellt werden 5 30 60 300 600 Sekunden Mit den Pfeiltasten Datalogintervall wählen und mit ENTER bestätigen Der angezeigte Wert kann mit den Pfeiltasten eingestellt und mit ENTER bestätigt werden Auf Werkseinstellung zurücksetzen Funktion Beschreibung ALARM Wenn die Alarmeinstellung aktiv ist ON ertönt ein akustischer Alarm wenn der eingestellte Grenzwert überschri...

Page 4: ...ogen wurde Index 1 Introduction 7 2 Kindly note 7 3 Delivery contents 7 4 Features at a Glance 7 5 Bedienung des Gerätes 5 1 LCD Display 8 5 2 Trend Chart 8 5 3 Trend Chart Zoom 8 5 4 Max Min 9 5 5 Real Time 9 5 6 SD Card For Logger 9 5 7 Main Menu Functions 9 1 Introduction Dear Sir or Madam Thank you very much for purchasing one of our products Before operating the data logger please read this m...

Page 5: ... over the current choice Note that after 1 minute if nothing is pressed the Main Menu will disappear and the device will revert to the normal state HOLD HOME To revert to start up settings at any point hold ENTER for 3 sec until an audible beep The device will revert to Home Setting displaying Back Home done Note that this is not the same as Restore to factory settings Below is a table showing wha...

Page 6: ...33mm Weight 103g only instrument without power supply 7 Rear View 8 Disclaimers USB connection is for power supply only no communication with PC Unplugging the device may result in loss of most recent logged data on the chart This device is not intended for workplace hazard CO2 monitoring nor intended as a definitive monitor for human or animal health institutions life sustenance or any medical re...

Page 7: ...changes any errors and misprints reserved Reproduction is prohibited in whole or part Stand05 2009CHB DOSTMANN electronic GmbH DOSTMANN electronic GmbH Mess und Steuertechnik Waldenbergweg 3b D 97877 Wertheim Reicholzheim Germany Phone 49 0 93 42 3 08 90 E Mail info dostmann electronic de Internet www dostmann electronic de ...