Operating Instructions for the

KOMET HSK Clamping Device HSK-A50 / 63

d

Clean surface of taper with lint free cloth.

d

Insert HSK tool into holder. Check the slots are correctly aligned at
the end of the taper. There is one deep slot and one shallower slot. It
is only possible to assemble one way.

d

A slight resistance will be felt because of pretensioning of the
orientation disc (i.e. the tool will positively engage).

d

Release the tool in order to apply the pretensioned orientation of the
cutting edge.

d

Apply hexagon key 8 mm A/F (use long style key).

d

To clamp: Turn the key clockwise 90° to 130° with a torque.
With torque wrench: HSK-A50 with 40 Nm, HSK-A63 with 70 Nm

d

achievable clamping force: 30 kN

d

To release: Turn the key anti-clockwise as far as the stop. Do not
apply force against the  stop!

d

The ejector on the HSK will be automatically activated when the
clamping is released.