EXPLANATION OF COMPONENTS
OPERATION
96
Avoiding excessive cooling.
●
If the operator feels somewhat cool when entering a cooled
cab, the temperature (temperature difference between exter-
nal temperature is 5° to 6°C) is at the optimum level from a
health viewpoint. Adjust the cooling temperature carefully.
FUSIBLE LINK
If the starting motor will not rotate when the starting switch is
turned ON, a possible cause is disconnection of wire-type fusible
link. Open the door on the left side of the machine body to inspect
the fusible link and, if necessary, replace it.
REMARK
A fusible link refers to the large-sized fuse wiring installed in
the high current flow portion of the circuit to protect electrical com-
ponents and wiring from burning, similar to an ordinary fuse.
CONTROLLERS
A pump and governor controller is provided. It is located in the
right, rear of the cab underneath panel assy (1).
NOTICE
●
Never splash or spill water, mud or drink over the con-
troller as this may cause a fault.
●
If a fault occurs in the controller, do not attempt repair,
but consult your Komatsu distributor.
TOOL BOX
This is used for keeping the tools.
REFUELLING PUMP
WARNING
Do not bring fire or sparks near the fuel.
1. When the machine is operated on sites with no fuel container
and pump, the machine may be refuelled using the refuelling
pump (if fitted) from fuel barrels.
The refuelling pump is located next to batteries at the front
right hand side of the machine.
2. Place the fuel hose (2), which is stored in tray (3) into the fuel
barrel placed next to the machine.
Summary of Contents for PW130ES-6K
Page 11: ...LOCATIONS OF PLATES TABLE TO ENTER SERIAL NO AND DISTRIBUTOR 10 ...
Page 56: ...55 OPERATION ...
Page 164: ...163 MAINTENANCE ...
Page 232: ...231 SPECIFICATIONS ...
Page 234: ...SPECIFICATIONS SPECIFICATIONS 233 1 PIECE BOOM ...
Page 235: ...SPECIFICATIONS SPECIFICATIONS 234 2 PIECE BOOM ...
Page 238: ...237 OPTIONS ATTACHMENTS ...