2.
Select the regeneration disable, press switch F6, and the
regeneration stops.
REMARK
The regeneration performed to protect the system may not
be stopped, but this is not a failure.
PROCEDURE FOR CANCEL OF AFTERTREATMENT DEVICES REGENERATION
DISABLE SETTING
k
k
CAUTION
When canceling the regeneration disable, move the machine to a safe place and check that there is no
person or combustible matter around the machine, and start the cancel operation.
1.
When switch F6 is pressed on the standard screen, “After-
treatment Devices Regeneration” screen is displayed.
(If the screen is not displayed, operate switches F1 and F2
to display “Aftertreatment Devices Regeneration” screen.
2.
Select Cancel of the regeneration disable and press switch
F6, and the regeneration disable is canceled.
If soot accumulation level (4) is lit 3 or more, the regenera-
tion is started automatically.
REMARK
• When canceling the regeneration disable, set the lock
lever to LOCK position and set the fuel control dial to
Low idle (MIN) position, then cancel the regeneration
disable.
• The regeneration disable setting is also canceled by
turning the starting switch to OFF position to stop the
engine.
EXPLANATION OF COMPONENTS
OPERATION
3-122
Summary of Contents for PC360LC-11
Page 2: ......
Page 22: ......
Page 76: ......
Page 344: ......
Page 425: ...SPECIFICATIONS 5 1 ...
Page 429: ...PC360NLC 11 SPECIFICATIONS SPECIFICATIONS 5 5 ...
Page 430: ......
Page 450: ...PC360LC 11 2 Piece Boom PC360NLC 11 2 Piece Boom 2 PIECE BOOM ATTACHMENTS AND OPTIONS 6 20 ...
Page 457: ...ATTACHMENTS AND OPTIONS 17M LONG REACH BOOM AND ARM 6 27 ...
Page 465: ...ATTACHMENTS AND OPTIONS SUPER LONG FRONT BOOM AND ARM 6 35 ...
Page 499: ...REPLACEMENT PARTS 7 1 ...
Page 515: ......