SEN04569-01
00-200
22
PC160LC-8
200 Foreword and general information
Handling of connectors newly used for engines
q
95, 125 – 170, 12V140 engines
4)
While pressing lock (E) of the connector,
pull out connector (5) in the direction of
the arrow.
Example)
Fuel pressure sensor in common rail:
PFUEL etc. (
AMP-3
)
Example)
Injection pressure control valve of fuel
supply pump: PCV (
SUMITOMO-2
)
Example)
Speed sensor of fuel supply pump:
G (
SUMITOMO-3
)
a
Pull the connector straight up.
4.
Turn-housing type (Round green connector)
q
140 engine
Example)
Intake air pressure sensor in intake mani-
fold (CANNON-04): PIM etc.
1) Disconnect connector (6) according to the
following procedure.
1]
Turn housing (H1) in the direction of
the arrow.
a
When connector is unlocked,
housing (H1) becomes heavy to
turn.
2]
Pull out housing (H1) in the direction
of the arrow.
a
Housing (H1) is left on the wiring har-
ness side.
2) Connect the connector according to the
following procedure.
1]
Insert the connector to the end, while
setting its groove.
2]
Turn housing (H1) in the direction of
the arrow until it “clicks”.