OPERATION
EXPLANATION OF COMPONENTS
3-7
CHECK MONITOR SYSTEM
3
MONITOR SYSTEM
NOTICE
q
Stop the machine on level ground and carry out the monitor check.
q
Stop the engine, then turn the starting switch to the ON position and check that the lamps light up for
approx. 2 seconds. If they do not light up, please ask your Komatsu distributor to carry out inspec-
tion.
q
The monitor check cannot be carried out until at least 5 seconds has passed after the engine was
stopped.
When carrying out the checks before starting, use the monitor system check.
1.
Turn the starting switch to the ON position.
2.
Check that the monitor liquid-crystal display and the lamps
all light up for 2 seconds, that the alarm buzzer sounds for
2 seconds, and that “KOMATSU SYSTEM CHECK“ is dis-
played for 3 seconds on display panel B (multi-information)
(1).
3.
q
After 2 seconds, the current status of the machine is
displayed on liquid-crystal display (2).
q
After 2 seconds, the lamp portion (3) goes out.
q
After 3 seconds, the operating mode is displayed on
display panel B (multi-information) (1).
REMARK
The following cases do not indicate any problem.
If the preheating heater is actuated in cold weather, HEAT lamp
(4) does not go out until the preheating is completed.
If the oil or filter replacement interval has been reached, main-
tenance caution lamp (5) or filter oil replacement interval lamp
(6) light up or flash for 30 seconds, and the action code is dis-
played on display panel B (multi-information) (1).
Summary of Contents for 69001
Page 2: ......
Page 3: ...FOREWORD 11 ...
Page 24: ...CONTENTS 1 22 ...
Page 54: ...PRECAUTIONS FOR MACHINE SAFETY 2 30 ...
Page 177: ...OPERATION TROUBLESHOOTING 3 123 ...
Page 178: ...TROUBLESHOOTING OPERATION 3 124 ...
Page 253: ...SPECIFICATIONS 15 ...
Page 270: ...EQUIPPING FIRE EXTINGUISHER AND FIRST AID KIT ATTACHMENTS OPTIONS 6 16 ...
Page 271: ...INDEX 17 ...
Page 272: ...INDEX 7 2 ...
Page 275: ...COLOPHON 18 ...