Kolpa Kolpa-San ZEPHYR 1680 3F Manual Download Page 10

 

 

 

www.kolpasan.eu 

massage cab is not allowed to have access to any parts containing live parts, 
except those supplied with safety extra-low voltage (SELV) not exceeding 12 V. 

o

  Children  are  allowed  to  use  the  appliance  without  supervision  only  if  

instructed  on  the  safe  use  massage  showers,  and  if  they  understand  the 
potential dangers in the event of improper use.  

o

  The device may only be connected to the mains electricity which is protected 

by means of a fault current protection switch FID 

IΔN 

 30 mA. The FID switch 

is designed to interrupt the phase conductor and the zero conductor in cases 
when the current flowing into the switch along the phase conductor is not the 
same as the one flowing out along the zero conductor.  

o

  The massage shower enclosure must be permanently connected to the power 

supply  network,  i.e.  plugging  it  into  a  socket  is  PROHIBITED.  In  addition,  it 
must  be  possible  to  switch  off  this  circuit  with  a  multipole  switch.  The  device 
enabling  the  separation  of  all  poles  from  the  power  supply  network  must  be 
integrated  within  the  electrical  wiring  in  line  with  the  national  wiring-related 
regulations.   

o

  The cable entry must be protected with a 16A safety fuse (3.5kW). Conductor 

cross-section = 2.5 mm

2

o

  The  device  may  only  be  plugged  into  the  mains  electricity  if  furnished  with  a 

ballast that disconnects the phase conductor and the zero conductor from the 
device. 

o

  The  manufacturer  or  repairer  of  this  device  (i.e.  the  massage  shower 

enclosure) is not responsible for the installation and proper functioning of both 
switches, i.e. FID and ballast. 

o

  The  additional  earth  conductor  (cross-section  =  6  mm

2

)  must  be 

connected to  the  connection  point for  equipotential  bonding,  which  is 
marked with the symbol shown on the right: 

o

 

While the steam bath is on, all parts of the person’s body must be at least 15 
cm away from the outgoing steam nozzle  in order to avoid  the risk of getting 
burned.   

o

  The continuous-flow water heater decreases the flow of hot water. Due to the 

different  pressure  of  hot  and  cold  water,  the  proper  functioning  of  the  water 
mixer  is  impeded.  In  such  cases,  no  complaints  on  the  grounds  of  improper 
mixer functioning shall be acknowledged. 

o

  The  low  flow  of  water  or  the  simultaneous  use  of  several  massage  functions 

will decrease the effect (i.e. the intensity) of the massage jet nozzles. 

o

  The massage shower enclosure may be connected to the water supply with a 

minimum pressure of 0.2 MPa (2 bar) or a maximum pressure of 0.4 MPa (4 
bar). Connecting it to higher water pressure is prohibited without installing an 
additional  device  intended  to  limit  the  water  pressure  and  set  at  0.4  MPa  (4 
bar).  Kolpa  d.d.  shall  not  acknowledge  complaints  arising  from  the  use  of 
water pressure that is higher than allowed for this product.  

o

  The  parts  which  contain  electrical  components  (with  the  exception  of  remote 

controls)  must  be  set  or  affixed  in  a  way  that  prevents  them  from  falling  into 
the  bathtub.  The  parts  that  contain  components  under  voltage,  with  the 
exception of parts under safety extra low voltage (SELV) that does not exceed 
12 V, may not be accessible to the person in the massage shower enclosure. 

o

  Certain  parts of  the massage  shower  enclosure feature  surfaces 

that  heat  up  to  such  an  extent  that  they  can  cause  burns  in  the 
event of direct contact or lengthy exposure at a distance of 10 to 
15 cm. Such surfaces feature a symbol shown on the right.  

Summary of Contents for Kolpa-San ZEPHYR 1680 3F

Page 1: ...ARIA SIMPLE radio ARIA QUAT A0 radio ARIA QUAT A3 radio MELBA SIMPLE radio MELBA M1 radio MELBA M3 radio ...

Page 2: ...1 www kolpasan eu PICTURE 1a ...

Page 3: ...2 www kolpasan eu PICTURE 1b ...

Page 4: ...3 www kolpasan eu PICTURE 2 ...

Page 5: ...4 www kolpasan eu PICTURE 3 ...

Page 6: ...5 www kolpasan eu PICTURE 4 ...

Page 7: ...6 www kolpasan eu PICTURE 5 ...

Page 8: ...7 www kolpasan eu PICTURE 6 ...

Page 9: ...ness and general danger o Alcohol drugs or medication before or during the use of massage cabins can significantly increase the risk of fatal hyperthermia or slipping o Do not perform unauthorised interventions that affect the safe and smooth operation of this product o Be careful when entering or leaving the hot tub cabin o Avoid massage or steam bath immediately after hard day s work or after st...

Page 10: ...conductor cross section 6 mm2 must be connected to the connection point for equipotential bonding which is marked with the symbol shown on the right o While the steam bath is on all parts of the person s body must be at least 15 cm away from the outgoing steam nozzle in order to avoid the risk of getting burned o The continuous flow water heater decreases the flow of hot water Due to the different...

Page 11: ...y using household vinegar which is more effective when it warms up o It is forbidden to use abrasive cleaning agents containing coarse fillers MAINTENANCE AND CLEANING INSTRUCTIONS FOR SHOWER ENCLOSURE BALL BEARINGS When cleaning the Kolpa San shower enclosures using the KOLPA SAN SPECIAL CLEANING AGENT which is very effective when it comes to removing limescale and thorough cleaning of other comp...

Page 12: ...g of an ANGLED connector or a 90 ELBOW for an easier connection and relieved joints o Kolpa d d does not recognise any claims which might arise from an inappropriate installation o Positions of electrical outlets hot and cold water drains and inlets as shown in the attached drawings and installation instructions are showing only one of the possible layouts of these connections Their position is al...

Page 13: ...required Where the water is heated through central heating one way valves are only required if property has a very large number of water customers multi apartment block or tower o In areas where the water contains a large quantity of particles impurities and scaling we recommend to install a device to remove or neutralize contaminants This increases the lifetime of massage pillars and greatly faci...

Page 14: ... the person in charge of the assembly has the right to refuse completing the assembly it the required assembly height is not enabled at the spot where the massage shower enclosure massage column is to be installed ELECTRICAL WIRING AND FITTINGS To ensure electrical safety please adhere to the instructions in this section and warnings in the PRECAUTIONS FOR USE section The massage shower enclosure ...

Page 15: ...t exceed 12 V may not be accessible to the person in the massage shower enclosure Figure 2 page 3 assembly area SETTING UP CONNECTIONS AND PREPARING THE SPACE FOR THE ARIA MASSAGE SHOWER ENCLOSURE EXTRACT FROM THE KOLPA SAN TECHNICAL CATALOGUE Picture 1 page 1 2 Warnings The massage shower enclosure may not be CONSTANTLY connected to the mains electricity it has to include a BALLAST to shut down t...

Page 16: ... enabled by raising the upper part of the mixer towards the left or the right The intensity of the water jet can be regulated by raising the lower handle The water temperature can be regulated by turning the lower handle towards the left or the right F1 Head shower F2 Hand shower F3 Back massage function F4 Lower body massage F3 Upper body massage CAUTION The intensity i e the effect of the massag...

Page 17: ... the system shuts down automatically If you would like to continue using this function turn it on by once again pressing the on key for the Turkish steam bath Right after the function is shut down either manually or automatically the process of rinsing off the steam generator is activated and lasts for app 5 minutes During this time the steam generator fills up with water several times and is empt...

Page 18: ...www kolpasan eu ...

Page 19: ...www kolpasan eu ...

Page 20: ...Rosalnice 5 SI 8330 Metlika SLOVENIJA tel 386 07 36 92 100 fax 386 07 36 92 166 PRODAJA SALE Kolpa d d Metlika Pod Barončevim hribom 4 SI 8000 Novo mesto SLOVENIJA tel 386 07 39 33 300 fax 386 07 39 33 350 e mail info kolpa si www kolpa si ...

Page 21: ...ARIA SIMPLE radio ARIA QUAT A0 radio ARIA QUAT A3 radio MELBA SIMPLE radio MELBA M1 radio MELBA M3 radio ...

Page 22: ...1 www kolpasan eu BILD 1a ...

Page 23: ...2 www kolpasan eu BILD 1b ...

Page 24: ...3 www kolpasan eu BILD 2 ...

Page 25: ...4 www kolpasan eu BILD 3 ...

Page 26: ...5 www kolpasan eu BILD 4 ...

Page 27: ...6 www kolpasan eu BILD 5 ...

Page 28: ...7 www kolpasan eu BILD 6 ...

Page 29: ...wirkungen der Hyperthermie zählen Hitze Erfassungsunfähigkeit bei der man nie die Notwendigkeit fühlt den heißen Raum verlassen zu müssen und von keiner drohenden Gefahr bewusst ist Sie kann Schäden dem Fötus bei schwangeren Frauen verursachen zu körperlicher Erschöpfung Verlust des Bewusstseins und allgemeiner Gefahr führen o Alkohol Drogen oder Medikamenten vor oder während der Verwendung von Ma...

Page 30: ...Schalters ausschalten kann Die Vorrichtung für die Trennung aller Polen vom Netz muss in die elektrische Installation in Übereinstimmung mit den nationalen Installationsvorschriften installiert werden o Die Stromversorgung muss mit einer 16A Sicherung 3 5kW gesichert werden Leitungsquerschnitt 2 5mm2 o Das Gerät darf nur dann ans Stromnetz angeschlossen werden wenn der Anschluss mit einem Vorschal...

Page 31: ...lt und die möglichen Partikel die die Öffnungen in den Massagedüsen verstopfen könnten entfernt werden Verwenden Sie ein sauberes Tuch um Chromteile zu wischen o Verwenden Sie flüssige Reinigungsmittel und ein weiches Tuch zu reinigen o Für die Reinigung von Acryl und anderen Kerrock oder Metalloberflächen und zum Entfernen vom Kalk wird der KOLPA SAN SPEZIALREINIGER empfohlen Spezialreiniger auf ...

Page 32: ...s dem ALU Kanal austritt Die Tür darf nur auf den oberen Lagern hängen 3 Heben Sie sanft die komplette Glastür und nehmen Sie diese aus dem ALU Kanal 4 Schmieren Sie die Lager 5 Hängen Sie die Glastür wieder ein Es wird empfohlen die Lager 1 2 jährlich einzuschmieren Nach Bedarf auch mehrmals je nachdem wie oft die Tür der Massagekabine geöffnet wird ALLGEMEINE WARNUNGEN ZUM ANSCHLUSS UND MONTAGE ...

Page 33: ...alliert ist und das Wasser ausschließlich für Ihre Wohnung oder Bad sperren kann dann ist die Installation eines weiteren Ventils nicht erforderlich WARNUNG Beachten Sie die Abmessungen des Ventils da die Massage Säulen sehr wenig Platz für den Anschluss ans Wassernetz lassen Wir empfehlen winkelige oder gerade Kugelhähne kleineren Abmessungen zu verwenden o Empfohlen wird die Installation der Was...

Page 34: ...AGEANLEITUNG Die Montage aller Massagekabinen Modelle des Unternehmens Kolpa d d wird seitens einer vom Händler bei welchem die Massagekabine gekauft wurde autorisierten Person durchgeführt In Slowenien ist das der offizielle Servicedienst des Unternehmens Kolpa d d In anderen Ländern sorgt dafür die offizielle Vertriebsstelle von Kolpa d d Bevor die Monteure die Massagekabine installieren und ans...

Page 35: ...ussstromleiter 3x2 5 mm2 mit Doppelschutzabschaltung Es muss ein zusätzlicher Erdungsleiter Querschnitt 6mm2 mit den Anschlusspunkt für den Ausgleich von Potenzialen verbunden werden markiert mit dem auf der rechten Seite gezeigten Symbol RAUM Der Raum in dem sich die Massagekabine befindet Badezimmer muss gemäß mit den in den einzelnen Ländern geltenden Vorschriften eingerichtet sein Auf der Stel...

Page 36: ...an den unteren Hebel nach oben hebt F1 Handbrause F2 Kopfbrause F2 Aria QUAT A0 Massagestrahlen Die Wassertemperatur wird so eingestellt dass man den unteren Hebel nach links beziehungsweise nach rechts dreht Die Massagekabinen ARIA QUAT A3 und MELBA M3 radio verfügen über eine 5 Funktions Armatur Die Funktionen werden so geändert dass man den oberen Teil der Mischbatterie nach links beziehungswei...

Page 37: ...l oder automatisch wird der Spülungsprozess des Wasserverdampfers eingeschaltet der etwa 5 Minuten lang dauert In dieser Zeit wird der Verdampfer mehrmals mit Wasser gefüllt und dann sofort entleert Während dieses Spülungsprozesses DARF DER STROM NICHT ABGESTELLT WERDEN Warnungen Kolpa d d übernimmt keine Verantwortung für Körperverletzungen die durch übermäßige Wassertemperaturen verursacht wurde...

Page 38: ...www kolpasan eu ...

Page 39: ...www kolpasan eu ...

Page 40: ...Rosalnice 5 SI 8330 Metlika SLOVENIJA tel 386 07 36 92 100 fax 386 07 36 92 166 PRODAJA SALE Kolpa d d Metlika Pod Barončevim hribom 4 SI 8000 Novo mesto SLOVENIJA tel 386 07 39 33 300 fax 386 07 39 33 350 e mail info kolpa si www kolpa si ...

Reviews: