20 CANopen Termination
RGM drive CAN addresses are assigned electronically via the serial port (connector P3) during the
commissioning process. See separate documents for further instructions.
l
RGM Workbench User Manual
l
RGM CANopen Manual
Note that the CANopen network requires 1 termination resistor at the source (master) and 1 termination
resistor at the final drive at the end of the network. RGM drive PCB is equipped with a jumper resistor at
connector location P2. Placing the jumper across both posts of connector P2 puts the termination resistor into
the circuit. Removing the jumper or moving it to a position that only contacts one of the P2 posts will remove
the termination resistor from the circuit.
RGM User Manual | 20 CANopen Termination
Kollmorgen | kdn.Kollmorgen.com | February 2019