Notes for installation
Remove
Before removing air conditioner to the other place, you should
contact the seller firstly.
Then it must be done under the direction of the professional
technician. In addition, the charge of this must be paid.
Noise
Electric wiring
Install in a location where is firm enough to avoid the enlargement of noise
and vibration.
Don’t put anything in front of the outlet of outdoor unit to avoid increasing
noise.
Be sure that hot air or
noise will not inconvenience neighbors.
Please contact the seller as soon as there is strange noise during operation.
Please use the safety support.
Must connect with ground reliably.
The exclusive circuit must be used. But removable socket can’t be used because poor
contact of it can cause over heat or fire.
If the supply cord is damaged,it must be replaced by the manufacturer or your dealer
In fixed circuit, there must be electricity leakage protection switch and leakage current
is less than 30mA.
Note:
Drain pan and drain hose must be installed before using reverse cycle models.
Drain hose or tubing can be purchased locally to satisfy your particular needs.
Don’t pull the power cord strongly.
or a qualified person to avoid a hazard.
An all-pole disconnection switch having a contact separation of at least 3mm in all poles
should be connected in fixed wiring
Connecting method between air conditioners and power cord and interconnecting method
The air conditioner should be installed in accordance with national wiring regulation.
All The
electric
al work must be done according to the local wiring regulations.
Air switch (thermal-magnetic breaker) should be installed in the circuit and its capacity
is
10A for
0.75hp
/
1.0hp
, 16A for
1.5hp
, 20A for
2.0hp
, 25A for
2.5hp
.
The cross section area for fixed wiring should be more than 2. 5mm
2
.
of each individual element with one another should accord with wiring diagram on the unit.