40 

5.1.1 AXBX Method 

1) Center Measurement. 

Set the equipment between the two code staffs of 30m. Then move the equipment closer 

to Staff B. As picture shown:   

 

 

 

 

 

 

 

The distance should meet the following conditions: 

    A. Station 1, the equipment should set in the center, the deviation should within 

±

1m, 

without focusing. 

    B. Station 2, b 

  2.5m 

2) Kukkamäki Method 

Set  the  equipment  between  the  2  staffs  in  a  m  away,  a  is  about  20m.  Then  set  the 

equipment  outside  the  staff  B,  the  distance  is b.  The  conditions  for  distance  are  same  to 

center measurement method.   

 

 

 

 

 

 

 

5.1.2 AXXB Method 

In AXXB method, the distance scale between each staff and station should be 1:2 

1) Förstner Method 

Summary of Contents for KL-03

Page 1: ...our dealer when necessary to receive our prompt service The meaning of following symbols DANGER It means the dangerous situation which might cause the human injury or even death WARNING It indicates...

Page 2: ...ghten the center screw Package and shock preventing Please reduce the shock or vibration during shipment The strong vibration might cause the function damage Please take off the battery when packaging...

Page 3: ...icial charger or battery Do not use broken cables plugs or sockets for power supply Do not put the battery in the fire or any high temperature environment otherwise it will cause the combustion and ex...

Page 4: ...the long term shipment by train air or sea The other carton can escape the shocking from outside in a certain way Storage Please keep the temperature between 30 70 Damp When the equipment is damped in...

Page 5: ...ses which caused by natural disasters such as earthquakes storms floods and fires accidents or any other third party liabilities The manufacture and dealer do not have any responsibility for the defec...

Page 6: ...1 4 Instrument Setup 09 1 5 Others 10 1 6 Optical Level 12 1 6 1 Height Measurement 12 1 6 2 Distance Measurement 13 1 6 3 Angle Measurement 13 2 OPERATION 14 2 1 Operation Keys 14 2 2 Main Menu 16 3...

Page 7: ...e 33 4 1 6 Line Tolerance 34 4 2 Memory Management 35 4 3 Export Data 36 5 ADJUST 38 5 1 Check 38 5 2 Dual axis Adjust 41 5 3 Reticle Cross hair 43 5 4 Circular Bubble 43 5 5 Tripod 43 6 CALC 44 6 1 L...

Page 8: ...e Cover 3 Eyepiece 4 Trigger Key 5 Focusing Hand Wheel Unit 6 Keyboard 7 Display Unit 8 Handle 9 Battery 10 Circle Bubble 11 U disk Port 12 RS232 COMM Port 13 Infinite Horizontal Tangent Unit 14 Optic...

Page 9: ...gnal inside Then it will get the height of sight line and the horizontal distance Please up right the staff vertically If you lighten the staff KL 03 can work at night 1 4 Instrument Setup Mount the K...

Page 10: ...cular vial C You can also adjust the bubble by electric 4 Focusing the lens A Aim at a bright background for example a piece of white paper B Rotate the eyepiece to clear the cross line C Aim at the c...

Page 11: ...minus Measurement at the top code KL 03 is available to aim at the bottom but it will influence the accuracy for level 5 The requirement for code s length in sight of view For precise measurement the...

Page 12: ...f vertically 3 Aim at the target roughly at first 4 Focus to the target by adjusting focusing screw 5 Aim at the target precisely by adjusting horizontal tangent 6 Check the bubble 7 Record the center...

Page 13: ...ht Measurement Upper cross hair 2 670 m bottom cross hair 2 502 m Interval L 0 168 m based on the formula distance 100 x L Distance d 16 8 m 1 6 3 Angle Measurement The bottom horizontal disk can be t...

Page 14: ...r measurement Users can improve the stability of measurement by averaging in multiple measurement Function Key Navigation key select correct item by control the cursor INT Switch to point to point mea...

Page 15: ...ting Press SHIFT PROG to enter is for illumination Press SHIFT DATA to activate PgUp Page Up Press SHIFT to enter PgDn Page Down Press SHIFT to enter Symbols on the screen 1 3 means the first of total...

Page 16: ...n as below Menu 1st Sub Menu 2nd Sub Menu Description 1 Meas Height Height Measurement Stake Out Stake Out Line Meas Level 1 Measurement Level 1 Measurement Level 2 Measurement Level 2 Measurement Lev...

Page 17: ...heck the digital level Dual axis Adjust Adjust the dual axis 4 Calc Line Adjustment Line adjustment 5 Set Quick Set Atmosphere correction earth curvature user key decimals set Complete Set Meas Settin...

Page 18: ...18 3 MEASUREMENT 3 1 Height Press Meas Height to enter the height measurement interface Input BS height by manual press Trigger Key to measure Press OK to check the result...

Page 19: ...rch the existed back sight point and height Press Trigger Key to measure this point You can choose Elevation Difference Height or Stadia stake out after press OK If the height is existed in the curren...

Page 20: ...Click the corresponding area to activate 2 Use to move the cursor and press ENT to confirm 3 Press numeric keyboard for example 1 for quick start The line tolerance has been settled in Level 1 4 Meas...

Page 21: ...Max Sight Ht 2 8 Min Sight Ht 0 65 dH Tolerance 0 0004 B B F F off B F Diff 1 Turn Diff off Level 2 aBFFB Total Stadia Diff 6 Max Stadia 50 Min Stadia 3 Max Sight Ht 2 8 Min Sight Ht 0 55 dH Tolerance...

Page 22: ...can choose BACK to the first point and re measure it 1 Start measure Press 4 Start After setting the tolerance the user can start measurement 2 Set a new job Move the cursor to Job press ENT to the se...

Page 23: ...it can be selected from the data list Pt Type Known point or measured point Search Input as a common character to find all the existed points 4 Set the tolerance Click 3 Tolerance to activate the tole...

Page 24: ...ined it by themselves On the other hand the equipment will monitor the distance between station and staff The distance is depend on the configurations Stadia Diff The difference between back sight dis...

Page 25: ...point In BF method the detail points and stake out points can switch under any BS or FS situation However in other methods the detail points and stake out points should be measured after finishing al...

Page 26: ...further help Press Next to choose Comm Port or Bluetooth measurement 3 4 1 Comm Port Choose 1 COM Port Setting the configurations then press Next to next page Comm port is only for remote control mea...

Page 27: ...e fine repeat mode will increase the quality of data especially under the unstable environment Average Average value for measurement in several times for example n 3 2 99 Limit Avg The equipment will...

Page 28: ...for example the value is 2 5 6 the median is 5 If n is even for example the value is 2 5 6 7 the median is 5 5 3 6 Function Press SHIFT FNC under any measure interface to enter the function setting pa...

Page 29: ...w code then press Save to confirm 3 6 4 Pt N Input the name of start point and interval for automatic increasing point number Point Name Management The start point will settle as A1 The FS point which...

Page 30: ...able for digital leveling Please use optical level mode to finish the job by inputting data by manual Please notice that 1 Consider the correction of earth curvature 2 Whether the value of inverse mea...

Page 31: ...luetooth device Press 2 or click the icon directly to enter 4 1 Edit Data Edit create view or delete the data of measure point known point job code line line tolerance Press 1 or click it on screen to...

Page 32: ...int 4 1 2 Known Point The data of known point should including the coordinate X Y H or only Height Choose the job and point name means all to search E N H means the coordinate for known point For Heig...

Page 33: ...um 8 property in 2 pages The code list will store at a fixed file All the job on this equipment can view edit or delete this code list Del Delete the existed code Add Add a new code into list It will...

Page 34: ...ance The user can view edit and add the tolerance standard in this interface The tolerance standard will store at a fixed file All the job on this equipment can view edit or delete it with maximum 10...

Page 35: ...anagement Check the information storage situation and memory formatting 4 2 1 Memory Info The user can check the job name existed quantity of lines and known points 4 2 2 Memory Format The formatting...

Page 36: ...ck Expt to confirm and export data It will create a folder named DEFAULT or the other job name under menu DL200 in U disk The data will be included in this folder If export to Bluetooth device the use...

Page 37: ...oth device as an example after select the job line name and data type click Find to search a new Bluetooth device for transfer Then press Next to confirm Input the folder s name by manual press Expt t...

Page 38: ...5 1 Check KL 03 has two kinds of adjust method The first is A X B X and the second is A X X B A B means the code staff X means the position for equipment Press 1 or click it directly to enter the che...

Page 39: ...staff except center measurement method at first The checking mode defined the distance range in default Once the distance is mismatch the equipment will show the corrective value for the position Afte...

Page 40: ...pment should set in the center the deviation should within 1m without focusing B Station 2 b 2 5m 2 Kukkam ki Method Set the equipment between the 2 staffs in a m away a is about 20m Then set the equi...

Page 41: ...Station 2 0 2 x D DIST_B2 0 4 X D 2 N bauer Method Set the equipment outside the staff a is about 15m 20m The conditions for distance should same as F rstner method It will display the i angle the cor...

Page 42: ...on is over 15 please adjust the dual axis by following steps 1 Adjust and leveling the equipment 2 Open the dual axis adjust page 3 Press OK and rotate 180 for second adjust 4 Confirm that the correct...

Page 43: ...1 Leveling the equipment 2 Rotate it in 180 3 Check whether the bubble has deviate to the center 4 If not please use an allen key to correct half of it Repeat step 1 4 until it centered 5 5 Tripod 1...

Page 44: ...job at first eg LINE001 in the picture The equipment can calculate the tolerance value of closure error in two methods Based on distance Tolerance value a b L L is the total length of this line Based...

Page 45: ...lculate the closure error and check the result If it is over range the equipment will show it on screen St Closure Err the closure error in each station Adj Method the adjustment method for example by...

Page 46: ...numeric key or click on screen to enter this setting page In Quick Set interface the user can change the settings for Atmosphere correction earth curvature user key and decimals 7 2 Complete Set In C...

Page 47: ...t Unit m or ft Format DL200 Earth Curvature On or Off Staff Invert On or Off Atmos Correction On or Off Atmos Constant User can input the atmosphere constant by manual 7 2 2 System 1 Sound Setting The...

Page 48: ...k light LCD auto back light control 3 Other Setting Date Display and set the system date The format is Year Month Day Time Display and set the system time in Hour Minute Second User Key User defined f...

Page 49: ...ata Export by U disk or Bluetooth I Angle display the current i angle It can be modified by manual 7 2 3 Instruction Info Click Ver to check the version of system measure module E bubble and model nam...

Page 50: ...50 7 2 4 Factory Mode Please notice that all the data will be recover under factory mode 7 3 E bubble...

Page 51: ...51 8 HELP 8 1 User manual In Help page the user can check the key note and adjust explanation in detail 8 1 1 Key Note 8 1 2 Adjust Explanation...

Page 52: ...mm 0 1 mm 0 01mm optional Distance 0 01m Measure Time 3 seconds Measure Mode Fine Fine Repeat Average Median Measure Method a BF BBFF a BFFB Code User defined Data Storage Internal Memory 128MBit 1500...

Page 53: ...Screen Value Correction Tilt Error Automatic Earth Curvature ON OFF Dimension L B H 230mm 225mm 203mm Weight Including battery 3 1kg Working Temperature 20 C 50 C Storage Temperature 40 C 70 C Protec...

Page 54: ...Total Stadia difference BS Stadia FS Stadia Total Stadia BS Stadia FS Stadia Station Distance BS Stadia FS Stadia Station Height Difference back staff record 1 back staff record 2 fore staff record 1...

Reviews: