Koldwave K6HK144BBA2ACA0 Owner'S Manual Download Page 2

2

3

Owner’s Manual

K6HK144BBA2ACA0 / K6HK144BEA2ACA0

Specifications 

(Continued)

Model No.

Indoor Air Flow  CFM

Refrigerant Type / oz(g)

K6HK144BBA2ACA0

4000

R-410A / 282(8000)

K6HK144BEA2ACA0

4000

R-410A / 278.7(7900)

Safety Devices

Compressor overload protector, Anti-freezing 

thermister, Automatic restart (Power interruption), 

Compressor time delay program, High pressure 

switch, Hot gas bypass

Features

Temperature control, Self-diagnostic function, 

Optional drain pump kit, Washable filters, °C display, 

Off-timer

PUMP-DOWN

The unit is integrated with 

PUMP-DOWN

 

function. PUMP-DOWN function keeps compressor 

running for 

certain time to protect compressor and other crucial 

parts before the unit or compressor is turned off. 

PUMP-DOWN function activates,

  - When the unit reaches target temperature

  - In between cooling mode to heating mode

  - In between cooling mode to Fan only operation

The unit operates in this particular way to protect the 

internal parts.

During PUMP-DOWN cycle, the compressor and fans 

will be keep operating even though user turns off the 

unit or turns off the compressor. 

Please do not forcefully switch off the unit or 

compressor during PUMP-DOWN cycle. The unit or 

compressor will turn off itself when it is safe for the 

unit to do so. 

Summary of Contents for K6HK144BBA2ACA0

Page 1: ...sumption Watts Rated Current Amps K6HK144BBA2ACA0 3Phases 220V 60Hz 144 400 18kW 57A K6HK144BEA2ACA0 3Phases 460V 60Hz 144 400 21 5kW 27A Model No Weight Net Gross Lbs kg Ambient tempera ture range F...

Page 2: ...integrated with PUMP DOWN function PUMP DOWN function keeps compressor running for certain time to protect compressor and other crucial parts before the unit or compressor is turned off PUMP DOWN func...

Page 3: ...operate the unit with wet or damp hands 12 DO NOT allow chemical substances to come into contact with the unit 13 DO NOT operate the unit near flammable substances or vapors such as alcohols pesticid...

Page 4: ...upright position on an even flat surface There must not be any objects or walls within 24 inches 60 cm from the unit 22 Halt the unit immediately if abnormal noise or odor is detected Contact your loc...

Page 5: ...OMPONENT PARTS Front and Right Side View Controls Hot Air Exhaust Electrical Panel Caster Condensate outlet I BOLT Cold Air Inlet Cold Air Inlet Filter Emergency Stop Controls Figure 2 Figure 3 Figure...

Page 6: ...and pinches in the ducting 3 Verify the termination points are not restricted meaning no objects are directly in front of the termination The Return Air In duct connection is labeled AIR IN The conne...

Page 7: ...t dust oil water or any other foreign material The unit is equipped with an approved NEMA plug configuration The appropriate outlet must be used for each plug type WARNINGS REGARDING PROPER LOCATION F...

Page 8: ...or 1 seconds Two digits on CURRENT TEMP indicate hour s and two digits on TARGET TEMP indicate minutes Set desired off time by pressing SET TEMP BUTTONS 5 ALARM Alarm indicator lights blinks and indic...

Page 9: ...nd are displayed when abnormal operation occurs 10 EMERGENCY STOP Emergency stop button immediately halts the operation 1 Press the red button Unit stops 2 Inspect the unit 3 Rotate the red button clo...

Page 10: ...ion Plate the purchase date purchase location serial number and war ranty period in the table below Also attach your purchase receipt as proof of purchase to this instruction manual for future referen...

Page 11: ...nd keep this manual for future reference and keep sales receipt as proof of purchase SELF DIAGNOSTIC CODES See Table 1 The alarm light is activated if abnormal operation occurs and a code is displayed...

Page 12: ...nnection Re connect the power cable to the correct power source Drain pump Applicapable for unit with drain pump Defective drain pump Improper water circulation Check the hose connection from drain pu...

Page 13: ...a qualified service agent Abnormal temperature sensor value TH1 Evaporator coil temperature sensor has a loose or broken connection Contact a qualified service agent Abnormal temperature sensor value...

Page 14: ...CP T 1 S 1 COM CO FUSE FUSE HIGH PRESSURE SWITCH E PBS R S T R S T R 2 S 2 T 2 S S 2A T 2A MC 2 OCR 2 R 3 S 3 T 3 R T COND MOTOR S R 3A S 3A T 3A MC 3 OCR 3 R 4A S 4A T 4A R T S No 1 EVA MOTOR T CP CP...

Page 15: ...R T COMP FND PS HP COM COM EXT FU FT CO COM R COM L H COM CP N 1 L 1 COM CO Power Remote Control Option EXT COM FUSE FUSE HIGH PRESSURE SWITCH PHASE PROTECTOR C CM B NC A NO R L1 S L2 T L3 TR 220V E...

Page 16: ...perly cooled if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned off and on quickly 2 Wait 2 minutes after unit is turned off before tu...

Page 17: ...17 Owner s Manual K6HK144BBA2ACA0 K6HK144BEA2ACA0...

Page 18: ...e Portable Air Conditioner Technical Support at 413 564 5520 Please have the following information available BEFORE calling the Technical Support Department a Your name and address b The serial number...

Page 19: ...19 Owner s Manual K6HK144BBA2ACA0 K6HK144BEA2ACA0 For Koldwave warranty please visit http koldwave com html literature asp...

Page 20: ...Owner s Manual K6HK144BBA2ACA0 K6HK144BEA2ACA0 Printed in April 2019 KOLDWAVE Sterling heating div Farmville 3576 S Fields st Farmville NC 27828 0809 USA PH 252 753 1921 Fax 252 753 1953 www koldwave...

Reviews: