Maintenance 

(Continued)

–  To ensure your product is covered by warranty, the complete faulty product along with your 

original purchase receipt must be provided at the place of purchase.

Product

Portable Air Conditioner

Model No.
Date of Purchase
Place of Purchase
Serial No.
Period of Warranty

Customer:

 Please read and keep this 

manual for future reference and keep 
sales receipt as proof of purchase.

SPRING REPLACEMENT 

(See Figure 12)

SELF-DIAGNOSTIC CODES 

(See Table 1)

The alarm light is activated if abnormal operation occurs, and a code is displayed on the control 
panel. The compressor and condenser fan motor will stop operating. The evaporator fan will con-
tinue to run for 3 minutes. If the fault is rectified within 3 minutes, the unit will resume opera-
tion. If the fault persists for more than 3 minutes, the evaporator fan also stops. The fault must 
be rectified before the unit can resume normal operation.

There are two springs on the rear of condensate water tank guide.
1. Release the screw on the spring hook.
2. Take off the spring hook, and then pull out the opposite spring
    hook from hole in the condensate water tank guide.
3. Replace with a new spring in reverse order.
4. Repeat this cycle for the other spring.

Figure 12 – The process of 
spring replacement

Summary of Contents for 6KK14BEA2AA00

Page 1: ...wing operat ing modes room and set temperatures and faults If an abnormal operation occurs a visual display of the fault is shown Caster wheels are included for easy portability Suitable applications...

Page 2: ...Refrigerant Type oz g Design Pressure Hi Low Psig 6KK14BEA2AA00 355 33 R 410A 21 2 600 465 160 6KK17BGA2AA00 430 40 R 410A 20 5 580 450 250 6KK21BGA2AA00 538 50 R 410A 24 3 690 484 148 Model No Indoor...

Page 3: ...for large areas where cooling of an entire area is not practical or possible Please read this manual before installing the 6KK14BEA2AA00 6KK17BGA2AA00 or 6KK21BGA2AA00 as it provides important informa...

Page 4: ...must be used with the product at all times When the filters are removed for clean ing always ensure that the unit has been turned off and unplugged from the electrical outlet 20 Regularly clean the fi...

Page 5: ...crews enclosed inside of box with the top fan exhaust flange to install the topfan exhaust flange on air condi oner as shown in Figure 6 TOP FAN EXHAUST FLANGE Figure 6 Figure 7 Figure 8 A B C An ambi...

Page 6: ...ther foreign material The unit is equipped with an approved NEMA plug configuration 6KK14BEA2AA00 5 15P 6KK17BGA2AA00 5 20P 6KK21BGA2AA00 6 15P The appropriate outlet must be used for each plug type W...

Page 7: ...system operation If Alarm oc curs compressor stops System operation stops when ALARM light is activated blinks longer than 3 minutes 7 CURRENT TEMP Displays current room temperature in display in Fahr...

Page 8: ...p of the filter in the guide and slide the filter up until the bottom of the filter clears the frame Then push the bottom of filter into the guide and let filter gently fall inside the guide NOTE For...

Page 9: ...ormal operation occurs and a code is displayed on the control panel The compressor and condenser fan motor will stop operating The evaporator fan will con tinue to run for 3 minutes If the fault is re...

Page 10: ...n 45 C 113 F Abnormal tempera ture sensor value TH1 Outlet tem perature sensor has a loose or broken connection Contact a qualified service agent Abnormal tempera ture sensor value TH2 Inlet tem perat...

Page 11: ...H1 TH1 OUT_TEMP SENSOR SEN1 SEN2 SEN3 TH2 TH2 TH3 TH3 IN_TEMP SENSOR ICE_TEMP SENSOR MC 1 OCR 1 C FAN MOTOR C C R S COMP Spark Arrestor FND PS HP COM COM EXT FU FT CO COM DRAIN PUMP Option L 2 N 2 COM...

Page 12: ...12 Owner s Manual 6KK14BEA2AA00 6KK17BGA2AA00 6KK21BGA2AA00 Wiring Diagram Figure 14 Circuit Wiring Diagram 6KK17BGA2AA00...

Page 13: ...properly cooled if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned off and on quickly 2 Wait 2 minutes after unit is turned off before...

Page 14: ...tioner Technical Support at 214 638 6010 Please have the following information available BEFORE calling the Technical Support Department a Your name and address b The serial number of the unit c Where...

Page 15: ...15 Owner s Manual 6KK14BEA2AA00 6KK17BGA2AA00 6KK21BGA2AA00 For Koldwave warranty please visit http koldwave com html literature asp...

Page 16: ...16 Owner s Manual 6KK14BEA2AA00 6KK17BGA2AA00 6KK21BGA2AA00 Printed in April 2019 KOLDWAVE 125 North Elm St Westfield Ma 01085 USA PH 252 753 1921 Fax 252 753 1953 www koldwave com...

Reviews: