Owner’s Manual

6KK14BEA2AA00 / 6KK17BGA2AA00 / 6KK21BGA2AA00

1

Owner’s Manual

WPC-3000, WPC-4000, WPC-5000

Owner’s Manual

6KK14BEA2AA00 / 6KK17BGA2AA00 / 6KK21BGA2AA00

Please read and save these instructions. Read carefully before attempting to assemble, install, oper-

ate or maintain the product described.

Protect yourself  and others by observing all safety information. Failure to comply with instructions 

could result in personal injury and / or property damage! Retain instructions for future reference.

Koldwave Portable Air Conditi oners feature spot cooling for 
large areas where cooling of the enti re area is not practi cal. 
A dedicated spot cooling thermostat controls the unit in this 
applicati on.
These air conditi oners can also be used in smaller areas for 
room cooling. A control panel provides ease of use and con-
tains a self-diagnosti c functi on and display, showing operat-
ing modes, room and set temperatures, and faults. 
If an abnormal operati on occurs, a visual display of the fault 
is  shown.  Caster  wheels  are  included  for  easy  portability. 
Suitable applicati ons include: a factory or work place, indus-
trial kitchen, computer room, emergency cooling, outdoor 
event, etc.

Aft er unpacking the unit, carefully inspect unit for any damage that may have occurred during 
transit. Check for any loose, missing, or damaged parts.

Descripti on

Unpacking

6KK14BEA2AA00, 6KK17BGA2AA00, 

6KK21BGA2AA00

Figure 1

Specifi cati ons

Model No.

Power Supply Ph-V-Hz

Cooling Capac-

ity Btu/h

Power Con-

sumpti on Watt s

Rated Cur-
rent Amps

EER Btu/

Wh

6KK14BEA2AA00

Single Phase, 115V, 60Hz

13,200

1300

11.9

11.0

6KK17BGA2AA00 Single Phase, 115V, 60Hz

16,800

1700

15.5

9.8

6KK21BGA2AA00 Single Phase, 208/230V, 60Hz

21,200

2400

11.3 / 10.9

8.8

Model No.

Nema Plug

Power Cord 

Gauge AWG

Power Cord 

Length ft 

Dimensions 

W x D x H - in. (mm)

6KK14BEA2AA00

5-15P

14

10

20.6 x 26.4 x 41 

(523 x 671 x 1042)

6KK17BGA2AA00

5-20P

12

6

6KK21BGA2AA00

6-15P

14

10

Portable Air Conditioners

Summary of Contents for 6KK14BEA2AA00

Page 1: ...wing operat ing modes room and set temperatures and faults If an abnormal operation occurs a visual display of the fault is shown Caster wheels are included for easy portability Suitable applications...

Page 2: ...Refrigerant Type oz g Design Pressure Hi Low Psig 6KK14BEA2AA00 355 33 R 410A 21 2 600 465 160 6KK17BGA2AA00 430 40 R 410A 20 5 580 450 250 6KK21BGA2AA00 538 50 R 410A 24 3 690 484 148 Model No Indoor...

Page 3: ...for large areas where cooling of an entire area is not practical or possible Please read this manual before installing the 6KK14BEA2AA00 6KK17BGA2AA00 or 6KK21BGA2AA00 as it provides important informa...

Page 4: ...must be used with the product at all times When the filters are removed for clean ing always ensure that the unit has been turned off and unplugged from the electrical outlet 20 Regularly clean the fi...

Page 5: ...crews enclosed inside of box with the top fan exhaust flange to install the topfan exhaust flange on air condi oner as shown in Figure 6 TOP FAN EXHAUST FLANGE Figure 6 Figure 7 Figure 8 A B C An ambi...

Page 6: ...ther foreign material The unit is equipped with an approved NEMA plug configuration 6KK14BEA2AA00 5 15P 6KK17BGA2AA00 5 20P 6KK21BGA2AA00 6 15P The appropriate outlet must be used for each plug type W...

Page 7: ...system operation If Alarm oc curs compressor stops System operation stops when ALARM light is activated blinks longer than 3 minutes 7 CURRENT TEMP Displays current room temperature in display in Fahr...

Page 8: ...p of the filter in the guide and slide the filter up until the bottom of the filter clears the frame Then push the bottom of filter into the guide and let filter gently fall inside the guide NOTE For...

Page 9: ...ormal operation occurs and a code is displayed on the control panel The compressor and condenser fan motor will stop operating The evaporator fan will con tinue to run for 3 minutes If the fault is re...

Page 10: ...n 45 C 113 F Abnormal tempera ture sensor value TH1 Outlet tem perature sensor has a loose or broken connection Contact a qualified service agent Abnormal tempera ture sensor value TH2 Inlet tem perat...

Page 11: ...H1 TH1 OUT_TEMP SENSOR SEN1 SEN2 SEN3 TH2 TH2 TH3 TH3 IN_TEMP SENSOR ICE_TEMP SENSOR MC 1 OCR 1 C FAN MOTOR C C R S COMP Spark Arrestor FND PS HP COM COM EXT FU FT CO COM DRAIN PUMP Option L 2 N 2 COM...

Page 12: ...12 Owner s Manual 6KK14BEA2AA00 6KK17BGA2AA00 6KK21BGA2AA00 Wiring Diagram Figure 14 Circuit Wiring Diagram 6KK17BGA2AA00...

Page 13: ...properly cooled if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned off and on quickly 2 Wait 2 minutes after unit is turned off before...

Page 14: ...tioner Technical Support at 214 638 6010 Please have the following information available BEFORE calling the Technical Support Department a Your name and address b The serial number of the unit c Where...

Page 15: ...15 Owner s Manual 6KK14BEA2AA00 6KK17BGA2AA00 6KK21BGA2AA00 For Koldwave warranty please visit http koldwave com html literature asp...

Page 16: ...16 Owner s Manual 6KK14BEA2AA00 6KK17BGA2AA00 6KK21BGA2AA00 Printed in April 2019 KOLDWAVE 125 North Elm St Westfield Ma 01085 USA PH 252 753 1921 Fax 252 753 1953 www koldwave com...