![Koldfront WAC10002WCO Service Manual Download Page 22](http://html1.mh-extra.com/html/koldfront/wac10002wco/wac10002wco_service-manual_1990547022.webp)
21
6.7 Auto-Defrost Function
The Auto-defrost function operates according to the chart below:
When TE is below 30
℉
the evaporator will frost. As the unit defrosts the indoor fan will continue
to operate.
When the temperature is up over 55
℉
the unit will stop defrosting.
6.8 Sleep Mode
This mode has a duration of 7 hours and can be used in Cool and Dry mode.
In sleep mode the fan speed will default to Auto.
In the first 60 minutes, the set temp will rise 2
℉
(1
℃
) each half hour. Then it will keep a steady
temperature for 6 hours until the mode stops.
If you change any settings after sleep mode starts, the function will stop.
TE
℉
55
30
compressor off
when TE is lower than 30
℉
lasting for 5 seconds
compressor on