background image

1. Mix 1/2 bag of KOLD-DRAFT ice machine cleaner (55R-01000) in one (1) liter

of clean, warm water (82°C. MAX.). 

2. If  the  cuber  is  operating,  wait  until  a  harvest  cycle  occurs  then  trip  the

"ICE-OFF-WASH" switch to "WASH" as soon as the water plate begins to close.

3. Empty  all  ice  from  the  storage  bin  and  shut  off  other  ice  makers  on  the  same

bin.

4. After the water fill is completed, switch  the "ICE-OFF-WASH" to "OFF".  While

pinching water level control hose, carefully remove the water level control tube

from the cap.  HOLD THE TUBE HIGH ENOUGH SO THAT THE TUBE DOES

NOT OVERFLOW.  Release the hose and pour about half of the mixed cleaner

into  the  tube.   Replace  the  tube  on  the cap,  while pinching  water  level  control

hose, then pour the remaining cleaner into the control stream box.

5. Switch  the  "ICE-OFF-WASH" to  "WASH"  and  allow  the  cleaner to  circulate  for

approximately 15 minutes, then pull the right side of the water plate down until

the pump stops and hold it until the pump will not re-start when released.

6. The water plate will open and dump the cleaner then close immediately, and the

water system will refill.  Repeat this dumping and refilling three (3) times to rinse

out all of the cleaning solution.

7. Mix  a  sanitizing  solution  of  60  ml  5-1/4%  sodium  hypochlorite  (household

bleach, or equivalent) and one (1) liter of clean water.

8. As  in  step  #4,  pour  about  half  of  the  sanitizing  solution  into  the  water  level

control tube and the remaining sanitizer into the control stream box.

9. Allow  the  sanitizing  solution  to  circulate  AT  LEAST  15  MINUTES,  then  dump

and rinse two (2) times as described above.  If necessary, reset the water level

probes to the proper levels.

10. While  the  cleaning  and  sanitizing  solutions  are  circulating,  clean,  rinse,  and

sanitize all accessible parts of the ice-making compartment of the cuber. 

11. After  cleaning  has  been  completed,  trip  the  "ICE-OFF-WASH"  switch  to  "ICE"

and check to be sure that the cuber is operating properly, particularly the water

level probes.  Then re-assemble and secure all cabinet enclosure panels.

508101502

Rev: 10-5-98

- 8 -

CAUTION

:

RISK OF PERSONAL INJURY OR PROPERTY DAMAGE

.

Do not use ammonia solutions in cleaning any part of the ice maker.
Do not mix ice machine cleaner and sanitizer together.
Use rubber gloves, eye protection, and an apron.
Clean up splashes or spillage immediately.
Follow these instructions exactly.

Summary of Contents for GT357 Classic

Page 1: ...GT357 KOLD DRAFT 1525 East Lake Road Erie PA 16511 1088 U S A Phone 814 453 6761 FAX 814 455 6336 2004 KDIndustries Inc Erie PA U S A Printed in U S A 3 04 508 1015 02 English with SI Units A Traditi...

Page 2: ...PMENT FAILURE OR FIRE Refer all maintenance to qualified personnel Never operate this equipment with covers panels or other parts removed or not properly secured Warn all users to clean up spillage im...

Page 3: ...top of bin if required 4 CAREFULLY place the cuber onto the gasketed bin 5 Install the drain pan ice chute Route the ice maker drain tube assembly through the rear of the bin and clamp the tubing to t...

Page 4: ...water supply line 8 Remove the water plate shipping strap 9 Route the bin thermostat capillary tube through the grommet in the right end frame wall and under the ice chute See the diagram below 50810...

Page 5: ...with PERMANENT CONNECTION TO THE ELECTRICAL SUPPLY fixed supply wiring connection Other operating condition requirements Ice maker ambient air temperature MINIMUM 8o C MAXIMUM 30 C Climate Class N tem...

Page 6: ...the batch of water then close immediately The water plate should stop when it is fully closed and the water fill cycle will repeat 5 After the water fill is complete move the ICE OFF WASH switch to t...

Page 7: ...THE FIRST PAGE and the importance of the PREVENTATIVE MAINTENANCE recommendations below PREVENTATIVE MAINTENANCE CLEANING 3 to 6 month intervals depending on water conditions INSPECTIONS During clean...

Page 8: ...he water system will refill Repeat this dumping and refilling three 3 times to rinse out all of the cleaning solution 7 Mix a sanitizing solution of 60 ml 5 1 4 sodium hypochlorite household bleach or...

Page 9: ...g the ice maker follow the ice maker cleaning instructions and clean the bin last 6 Replace all enclosure panels before re connecting the electrical supply WINTER CONDITIONING Ice cubers which are idl...

Page 10: ...508101502 Rev 10 5 98 10...

Reviews: