1. Mix 1/2 bag of KOLD-DRAFT ice machine cleaner (55R-01000) in one (1) liter
of clean, warm water (82°C. MAX.).
2. If the cuber is operating, wait until a harvest cycle occurs then trip the
"ICE-OFF-WASH" switch to "WASH" as soon as the water plate begins to close.
3. Empty all ice from the storage bin and shut off other ice makers on the same
bin.
4. After the water fill is completed, switch the "ICE-OFF-WASH" to "OFF". While
pinching water level control hose, carefully remove the water level control tube
from the cap. HOLD THE TUBE HIGH ENOUGH SO THAT THE TUBE DOES
NOT OVERFLOW. Release the hose and pour about half of the mixed cleaner
into the tube. Replace the tube on the cap, while pinching water level control
hose, then pour the remaining cleaner into the control stream box.
5. Switch the "ICE-OFF-WASH" to "WASH" and allow the cleaner to circulate for
approximately 15 minutes, then pull the right side of the water plate down until
the pump stops and hold it until the pump will not re-start when released.
6. The water plate will open and dump the cleaner then close immediately, and the
water system will refill. Repeat this dumping and refilling three (3) times to rinse
out all of the cleaning solution.
7. Mix a sanitizing solution of 60 ml 5-1/4% sodium hypochlorite (household
bleach, or equivalent) and one (1) liter of clean water.
8. As in step #4, pour about half of the sanitizing solution into the water level
control tube and the remaining sanitizer into the control stream box.
9. Allow the sanitizing solution to circulate AT LEAST 15 MINUTES, then dump
and rinse two (2) times as described above. If necessary, reset the water level
probes to the proper levels.
10. While the cleaning and sanitizing solutions are circulating, clean, rinse, and
sanitize all accessible parts of the ice-making compartment of the cuber.
11. After cleaning has been completed, trip the "ICE-OFF-WASH" switch to "ICE"
and check to be sure that the cuber is operating properly, particularly the water
level probes. Then re-assemble and secure all cabinet enclosure panels.
508101502
Rev: 10-5-98
- 8 -
CAUTION
:
RISK OF PERSONAL INJURY OR PROPERTY DAMAGE
.
Do not use ammonia solutions in cleaning any part of the ice maker.
Do not mix ice machine cleaner and sanitizer together.
Use rubber gloves, eye protection, and an apron.
Clean up splashes or spillage immediately.
Follow these instructions exactly.
Summary of Contents for GT357 Classic
Page 10: ...508101502 Rev 10 5 98 10...