INSTALLATION SPECIFICATIONS
READ THE FOLLOWING NOTES CAREFULLY PRIOR TO MAKING CONNECTIONS
REQUIREMENTS
Electrical
:
THE INSTALLER MUST PROVIDE REQUIRED BRANCH CIRCUIT OVERCURRENT
PROTECTION (FUSES) AND DISCONNECTION MEANS.
230 V +/- 10%
50 Hz
6,7 A; 1 350 W
Water supply
: Minimum 200 kPa supply pressure while the ice maker is filling is
required. Maximum supply pressure is 690 kPa. The water fill flow rate is 2.3 l/min.
Backflow or backsiphonage prevention devices, if required, must be provided by the
installer.
Ice maker drain
: Do not reduce the drain tube size.
All models are FOR INDOOR USE ONLY with PERMANENT CONNECTION TO THE
ELECTRICAL SUPPLY (fixed supply wiring connection).
Other operating condition requirements:
Ice maker ambient air temperature: MINIMUM 8
o
C.; MAXIMUM 30°C.
Climate Class "N" (temperate).
Potable water and condenser liquid supply:
Temperature: MINIMUM 8°C.; MAXIMUM 30°C.
Pressure: MINIMUM 200 kPa; MAXIMUM 690 kPa*
*If regulator is used, recommended setting is 200 to 345 kPa.
Liquid condenser coolant regulator
: The condenser coolant (water) regulating valve
may require adjustment to provide approximately 40
o
C condensing temperature (1 720
kPa high-side pressure).
508101502
Rev: 10-5-98
- 5 -
CAUTION
:
RISK OF PROPERTY DAMAGE, EQUIPMENT FAILURE, OR FIRE
.
Failure to comply with all installation specifications and instructions may cause
erratic operation and the risk of damage or fire.