INSTALLATION SPECIFICATIONS

READ THE FOLLOWING NOTES CAREFULLY PRIOR TO MAKING CONNECTIONS

REQUIREMENTS

Electrical

:

THE  INSTALLER  MUST  PROVIDE  REQUIRED  BRANCH  CIRCUIT  OVERCURRENT
PROTECTION (FUSES) AND DISCONNECTION MEANS.

230 V +/- 10%
50 Hz
6,7 A;  1 350 W

Water  supply

:    Minimum  200  kPa  supply  pressure  while  the  ice  maker  is  filling  is

required.    Maximum  supply  pressure  is  690  kPa.    The  water  fill  flow  rate  is  2.3  l/min.
Backflow  or  backsiphonage  prevention  devices,  if  required,  must  be  provided  by  the
installer.

Ice maker drain

:  Do not reduce the drain tube size.

All  models  are  FOR  INDOOR  USE ONLY  with  PERMANENT  CONNECTION  TO  THE
ELECTRICAL SUPPLY (fixed supply wiring connection).

Other operating condition requirements:
Ice maker ambient air temperature:  MINIMUM 8

o

C.;  MAXIMUM 30°C.

Climate Class "N" (temperate).
Potable water and condenser liquid supply:
  Temperature:  MINIMUM 8°C.;  MAXIMUM 30°C.
  Pressure:   MINIMUM 200 kPa;  MAXIMUM 690 kPa*
  *If regulator is used, recommended setting is 200 to 345 kPa.

Liquid condenser coolant regulator

:  The condenser coolant (water) regulating valve

may require adjustment to provide approximately 40

o

 C condensing temperature (1 720

kPa high-side pressure).

508101502

Rev: 10-5-98

- 5 -

CAUTION

:

RISK OF PROPERTY DAMAGE, EQUIPMENT FAILURE, OR FIRE

.

Failure to comply with all installation specifications and instructions may cause
erratic operation and the risk of damage or fire.

Summary of Contents for GT357 Classic

Page 1: ...GT357 KOLD DRAFT 1525 East Lake Road Erie PA 16511 1088 U S A Phone 814 453 6761 FAX 814 455 6336 2004 KDIndustries Inc Erie PA U S A Printed in U S A 3 04 508 1015 02 English with SI Units A Traditi...

Page 2: ...PMENT FAILURE OR FIRE Refer all maintenance to qualified personnel Never operate this equipment with covers panels or other parts removed or not properly secured Warn all users to clean up spillage im...

Page 3: ...top of bin if required 4 CAREFULLY place the cuber onto the gasketed bin 5 Install the drain pan ice chute Route the ice maker drain tube assembly through the rear of the bin and clamp the tubing to t...

Page 4: ...water supply line 8 Remove the water plate shipping strap 9 Route the bin thermostat capillary tube through the grommet in the right end frame wall and under the ice chute See the diagram below 50810...

Page 5: ...with PERMANENT CONNECTION TO THE ELECTRICAL SUPPLY fixed supply wiring connection Other operating condition requirements Ice maker ambient air temperature MINIMUM 8o C MAXIMUM 30 C Climate Class N tem...

Page 6: ...the batch of water then close immediately The water plate should stop when it is fully closed and the water fill cycle will repeat 5 After the water fill is complete move the ICE OFF WASH switch to t...

Page 7: ...THE FIRST PAGE and the importance of the PREVENTATIVE MAINTENANCE recommendations below PREVENTATIVE MAINTENANCE CLEANING 3 to 6 month intervals depending on water conditions INSPECTIONS During clean...

Page 8: ...he water system will refill Repeat this dumping and refilling three 3 times to rinse out all of the cleaning solution 7 Mix a sanitizing solution of 60 ml 5 1 4 sodium hypochlorite household bleach or...

Page 9: ...g the ice maker follow the ice maker cleaning instructions and clean the bin last 6 Replace all enclosure panels before re connecting the electrical supply WINTER CONDITIONING Ice cubers which are idl...

Page 10: ...508101502 Rev 10 5 98 10...

Reviews: