2. Know more about your Heat Pump
Safety Features
Time Delay. All models are preset at 3 minutes compressor time delay (F21 Parameter code in LED
display) to prevent the compressor from breaking by frequent boot. In addition, the controller doesn’t
boot the compressor within 3 minutes after turning on the power supply, thus it can also be protected
in the state of power being off and on in short time.
Water Pressure Switch
.
Heater will stop if water pressure is lower than operating level at 0.1kg/cm
2
. It
will restart automatically after backing to normal pressure.
High/Low refrigerant pressure switch. Heater will stop when refrigerant pressure is unsafe reaches
4.1MPa or 0.15 MPa. It will restart automatically after backing to normal pressure.
Technical Data
MODEL
K880
K881
K882
K883
K884
K885
BTU/H
8500
14000
22000
29000
34000
43000
HEATING
CAPACITY
W
2500
4200
6500
8500
10000
13000
POWER INPUT
W
500
850
1300
1700
2000
2600
EFFICIENCY
COP
5
5
5.08
5
5
5.08
STATED
CURRENCY
A
2.3
4.1
6.8
8.3
9.2
12.0
POWER INPUT
V/PH/HZ
220/1/50
220/1/50
220/1/50
220/1/50
220/1/50
220/1/50
COMPRESSOR
QUANTITY
1
1
1
1
1
1
COMPRESSOR
TYPE
ROTARY
ROTARY
ROTARY
ROTARY
ROTARY
ROTARY
HEAT
EXCHANGER
PVC HERMETIC WATER BARREL WITH SPIRAL SOFT TITANIUM PIPES IN SIDE
Summary of Contents for K2O K880BX/EU
Page 1: ......
Page 8: ...7 Electric circuit diagram...
Page 13: ...12 Filtration System Layout Shared Filtration System...
Page 14: ...13 Independent Filtration System...
Page 35: ...34 SCHEMA ELECTRIQUE...
Page 40: ...39 Sch ma d installation du syst me de filtration Syst me de filtration partag...
Page 41: ...40 Syst me de filtration ind pendant...
Page 60: ...59...