Handling and Safety Precautions

These precautions should be strictly observed in order to ensure safe, 

long-term use of the product.

The following precautions should be observed particularly strictly:

Obstetric model - vulva II and the umbilical cord kit (for tying and cutting)

1.  This model is made with a special material to simulate the texture of human skin. Please handle 

it with the same care that you would exercise when working with a human body. Pulling it with 
excessive force or subjecting it to strong impact, such as dropping it, may cause damage.

2.  The material of this model has a distinct odor, which fades with time. This odor is not harmful 

to the human body and does not indicate poor quality. There may also be a baby powder smell 
remaining on the product, as baby powder is applied to the models during fabrication.

3.  Wear disposable gloves when handling the model.
4.  Use glycerin to lubricate the models. Be sure to apply a sufficient amount of lubricant (glycerin) 

to the model before use. Koken is not responsible for deterioration or damage occurring from 
use of lubricants other than glycerin. Use commercially available glycerin if you run out of the 
glycerin provided with the model.

5.  Placing objects directly on top of the model or placing the model on uneven surfaces may result 

in deformation.

6.  Do not use rubbing alcohol, thinners, benzene or other similar organic solvents on the model, as 

doing so may cause damage.

7.  Do not use oil-based inks, pencil, chalk, or paints on the model, as they will soak into the material 

and cannot be removed.

8.  If the surface becomes sticky after washing the model, generously apply baby powder to the 

model to reduce friction.

9.  The model may lose its shape after a long period of time. Check the shape of the model around 

3 years after purchase. If it is deformed to the extent that functioning is affected, please consider 
ordering a replacement.

10. Air bubbles or impressions in the model that may remain from the fabrication process do not 

affect the strength of the material, as the material used is highly tear-resistant.

11. This model is washable. After washing, wipe off the remaining water with a soft, dry gauze or 

cloth, and pat baby powder all over the model. 

(Do not clean the model with rubbing alcohol, 

thinners, benzene or other similar organic solvents.)

Summary of Contents for LM-101B

Page 1: ...Obstetric Assistant Model Set Obstetric Model Vulva II Please read this instruction manual carefully to ensure correct use of the product and store it in a safe place for easy access KOKEN CO LTD 1 4...

Page 2: ...10000...

Page 3: ...occurring from use of lubricants other than glycerin Use commercially available glycerin if you run out of the glycerin provided with the model 5 Placing objects directly on top of the model or placin...

Page 4: ...result in damage to the model 2 When delivering the placenta avoid pulling too strongly on the umbilical cord 3 Using the umbilical cord clip on the placenta model umbilical cord may cause it to tear...

Page 5: ...l In particular the product should not be used in any way that contravenes the precautions noted in the instruction manual 5 Wash smudges or marks off the model with water To clean stubborn smudges or...

Page 6: ...4 Table of Contents 1 Outline and Features 2 Parts of the Obstetric Assistant Model Set 3 Using the set 4 Caring for the Model 5 Specifications 6 Accessories and Optional Items...

Page 7: ...ricate Protection of the perineum can be practiced Breech extraction can also be practiced as one type of emergency response The umbilical cord is soft and slides away from scissors when being cut so...

Page 8: ...6 2 Parts of the Obstetric Assistant Model Set Fetal model Placenta model Main body Obstetric model vulva II Fixing screws Umbilical cord Umbilical cord connector...

Page 9: ...d to the placenta model LM 0634 until a hook appears on the end 6 3 Using the set 3 1 Attaching the obstetric assistant model vulva II Place the obstetric assistant model vulva II on the main body and...

Page 10: ...very Make sure the parts are not lubricated when attaching them together as it will be difficult to slide the umbilical cord of the placenta model over the umbilical cord for tying and cutting if they...

Page 11: ...y covered by the umbilical cord connector they may come apart 6 Assembly is now complete To re attach the umbilical cord for tying and cutting after it is cut off start the procedure again from step 5...

Page 12: ...assistant model vulva II to the head and shoulders of the fetal model and to the placenta model 3 4 Holding the fetal model Hold down the back of the head of the fetal model with your index finger to...

Page 13: ...h water Do not clean the model with rubbing alcohol thinners benzene or other similar solvents When washing the model do not dig your nails into the surface or apply strong force This may result in da...

Page 14: ...otal length Diameter Weight Umbilical cord connector 1 Approx 4 cm Approx 1 6 cm Approx 7 g Fixing screw 2 Accessories Product name Quantity Cloth cover for main body 1 Glycerin 1 Instruction manual 1...

Reviews: