Kohler VEIL K-5402A-0 Homeowner'S Manual Download Page 13

rear

dryer

stop

front

flush

lighting

Kohler Co.

13

1274372-A05-C           May 2018

Click remote UV button to perform UV sterilization function when toilet cover is CLOSED. This process takes about 

34 minutes. 

During UV sterilization process, sterilization will be deactivated if customer opens cover and sits on toilet,

or presses STOP button on side panel. 

Press to activate dryer function

Light induction zone 

Press night light function down (long beep indication) 

Press again to activate night light function (short beep 

indication). 

Press to enter rear wash

STOP function

Press to flush the toilet

Note:

Note:

UV Sterilization Function

Side Panel Function

UV sterilization function is used to sterilize wand by UV light. 

Auto UV sterilization 

E-water Function 

E-water function is used to sterilize nozzle by E-water. 
Toilet shall activate E-water sterilization function after user completes front wash, rear wash or spiral wash etc. 
E-water sterilization function with automatically activate every 8 hrs when toilet is not in use.

 

 

Auto activates UV sterilization function to sterilize wand if not used for a long time. The process takes about 45 

minutes. This function will not be reactivated within the next 24 hrs. 
During UV sterilization process, sterilization will be deactivated if customer opens cover and sits on toilet, or

presses STOP button on side panel. 
For auto UV sterilization function setting, refer to Page 8.

Manual UV sterilization

Press to enter front wash

1. Each function begins on factory defaults. User can change settings by remote (see remote setting guide, pg7~8).
2. Press STOP during front or rear wash to cease function. This will automatically switch off after 5 minutes.

3. Press STOP during dryer operation to cease function. This will automatically switch off after 4 minutes.

Summary of Contents for VEIL K-5402A-0

Page 1: ...Homeowners Guide 1274372 A05 C May 2018 Veil Intelligent Toilet Wall Hung K 5402A 0 Wall Faced K 8423A 0 Veil Wall Hung Veil Wall Faced...

Page 2: ...Do not immerse product within water IMPORTANT Risk of product damage Do not install seat in a location where water might be splashed on the product IMPORTANT Risk of product damage Do not install this...

Page 3: ...unit Keep the cord away from splash water Avoid low grade burn from exposed skin contact heating seat for a long time Only authorized persons from manufacture maintenance or similar departments may r...

Page 4: ...Thermal protection Temp fuse overheat breaker Back flow prevention Check valve Thermal Temp adjustment OFF 1 5 dials ambient temp 31 39 Safety device Temp fuse overheat breaker Cover Auto OPEN CLOSE s...

Page 5: ...the care and cleaning instructions All information in this manual is based upon the latest product information available at the time of publication At Kohler we constantly strive to improve the quali...

Page 6: ...after about 5 minutes or will turn off immediately upon pressing the OFF button H Stop Press this button to stop front wash rear wash dryer and deodorizer manual wand clean and UV etc functions Pressi...

Page 7: ...e dryer button after bottom row of icons quick blinking toilet operation starts Hold toilet button and button on toilet side panel release button when heard one short beep When the bottom row of icons...

Page 8: ...Press and hold manual clean wand function under unseated status to extend wand to perform manual clean on nozzle Press and hold this button again or press STOP button to deactivate this function Remot...

Page 9: ...nking during this process When night light stops blinking self checking procedure is complete Default status settings for initial use Front wash Water temp mid Water flow mid Wash position 3rd dial Re...

Page 10: ...e OPEN CLOSED manually When user opens closes cover normally cover shall automatically open close based on the movement trend Do not continue to apply force to cover Cover shall automatically stop whe...

Page 11: ...when meeting with an obstruction during movement Note During cover and seat OPEN CLOSE process do not apply excessive force to cover or seat Any man made interference on cover or seat during automatic...

Page 12: ...flush is deactivated Press manual flush button on flush control board Left button flush full Right button flush ECO half flush Note 1 User shall be able to use remote to control flush water or manual...

Page 13: ...e by E water Toilet shall activate E water sterilization function after user completes front wash rear wash or spiral wash etc E water sterilization function with automatically activate every 8 hrs wh...

Page 14: ...completely with water immediately after applying cleanser Rinse and dry any overspray that lands on nearby surfaces Cleaning seat Do not use abrasive detergent and sterilizing aerosol spray products N...

Page 15: ...panel when not sitting on toilet to extend the wand for cleaning or inspection Clean the spray wand without removing the tip Just use a wet soft bristled brush to clean Clean the spray wand by removin...

Page 16: ...e filter screen and clean Reinstall filter screen connect to hose connector open valve Turn on power supply and check for leaks Reinstall side panel 2 Concealed water tank filter screen clean Please f...

Page 17: ...rrs Deodorizer block exchange steps Remove deodorizer screen and deodorizer block Screen After exchanging deodorizer block re install back to the toilet Deodorizer block Deodorizer block bracket Note...

Page 18: ...ED OFF Note 1 Residual water may freeze in winter and cause damage if toilet is not discharged completely over long idle times 2 Any water remaining in the seat may freeze during winter allow the unit...

Page 19: ...P button during operation C Auto deodorizing function is disabled A Remove object or wipe seat B If needed sit on again after 2 seconds C Refer to Remote setting guide section working 9 Unable to open...

Page 20: ...ith float C Clean float with water from inlet valve 17 No water when A Wrong adjusting board and screw rod installation B Discharge valve lever and barb is not connected A Re install screw rod B Re in...