background image

-2-

TOOLS AND MATERIALS REQUIRED
(Not supplied)

·

·

·

·

·

·

·

·

·

·

·

·

·

254mm (10") adjustable wrench
305mm (12") pipe wrench
Metal file (file cut)
Tape measure
Tubing cutter
Level
Hacksaw
Putty knife
Screwdriver
Toilet gasket (wax seal)
Toilet installation flange
Toilet T-bolts (2), 8mm (5/16") diameter
Toilet supply shut-off valve

If the existing toilet does not have a shut-off valve

below the tank, install one before installing the new toilet.

* Flexible hose are recommended to connect the supply line
to the fill valve. If you use a rigid connection, take care not to
apply side forces to the bottom of the fill valve.

NOTICE:

·

·

·

·

·

·

·

·

·

·

·

·

·

254mm
305mm

(

)

8mm

T

(2

)

*

·

·

Carefully inspect the new fixture for any sign of
Damage.
For new construction, refer to the dimensions in

and

for locating the shut-off valve.

The fill valve

nut has been factory-tightened to design specifications.
If re-tightening is required, wrench tighten 1/4 turn past
finger tight.

Fig. #1

Fig. #3

WARNING: Risk of external leakage.

·

·

Fixture dimensions are nominal and conform to tolerances
established by ASME Standards (A112.19.2-2018).
This product complies with Q/KCI-006-2018 and GB
25502-2017. Water Efficiency Grade 2.

·

·

1

3

1/4

·

·

ASME

(A112.19.2-

2018)

Q/KCI-006-2018

GB 25502-2017

2

Fig.#1

1

Unit: mm

:

Kohler reserves the right to change marked dimensions without prior notice.

Reference Value

Finished
Wall

305/400

390

277

320

372

225

299

299

200

190

755

718

373

1355511-T01-A

Summary of Contents for VEIL K-1666T-S

Page 1: ... K 1660T Includes Tank K 1664T SLT3 VEIL Class Five 2PC Toilet 400mm K 1667T SL Includes Bowl K 2597T Includes Tank K 1664T SLT4 Includes K 4141T Includes K 4141T Includes Elongated Slim Seat K 77070T Includes Elongated Slim Seat K 77070T Quiet Close Quiet Close 305mm K 1666T S K 1660T K 1664T ST3 400mm K 1667T S K 2597T K 1664T ST4 305mm K 1666T SL K 1660T K 1664T SLT3 400mm K 1667T SL K 2597T K ...

Page 2: ... 254mm 305mm 8mm T 2 Carefully inspect the new fixture for any sign of Damage For new construction refer to the dimensions in and for locating the shut off valve The fill valve nut has been factory tightened to design specifications If re tightening is required wrench tighten 1 4 turn past finger tight Fig 1 Fig 3 WARNING Risk of external leakage Fixture dimensions are nominal and conform to toler...

Page 3: ...k or cause damage Kohler is not responsible for any damage caused by installation with the use of cement mm 67mm 200mm 190 Fig 3 3 Fig 4 4 Fig 5 5 TO INSTALL SUPPLY SHUT OFF VALVE Install the supply shut off valve so it is 200mm above the finished floor line and 190mm to the left of the closet flange centerline The centerline of the supply shut off valve outlet should extend 67mm from the finished...

Page 4: ...1 2 o C Fig 6 6 Install brackets Plastic Trap Outlet Toilet Gasket Fig 8 8 Fig 9 9 Fig 10 10 Install plastic to ground and mounted with 3 set of bolts not supplied firmly Carefully align and lower the bowl Apply weight to the bowl rim to let the outlet insert into plastic trap Carefully thread the screws into the brackets until toilet is secure Alternately tighten left and right sides to prevent p...

Page 5: ...ater supply off Replace END by engaging lugs and rotating 1 8 turn clockwise Turn on water supply Check that water level is at the marked water line 1 8 1 8 TO CONNECT WATER SUPPLY Flexible hose not provided are recommended to connect the supply line to the fill valve If you use a rigid connection not provided take care not to apply side forces to the bottom of the fill valve Be sure the rigid con...

Page 6: ...e continues to run allowing water to enter tank 3 Incorrect water level height A Foreign particles lodged under the float valve seal located under fill valve cap B Fill valve seal located under float valve cap may be cracked or split C Tank water level set above overflow level D Water leaking past flush ball E Trip lever binding holding flush ball open A Shut off water supply remove fill valve cap...

Page 7: ...1 A B A B A B C D E A 1 8 1 8 B C D E 2 3 A B A B 4 A 2A A 5 A B C D A B C D 6 A B A B 7 1355511 T01 A ...

Page 8: ... cleaners or solvents Do not use in tank cleaners Products containing chlorine calcium hypochlorite can seriously damage fittings in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing chlorine calcium hypochlorite WARNING Risk of property or product damage 0 C o ...

Reviews: