Fig.#11

11

Apply caulk around base.

IMPORTANT:

Make certain the top is turned to the locked

position. Valve may not turn on if top is not fully in the
locked position.

Before turning on the supply valve for the first

time, follow the steps below to clear sand, debris and rust
from the system:

Make sure water sure water supply is off. Remove valve END
by rotating it 1/8 turn counterclockwise.

While holding a container over the uncapped VALVE to
prevent splashing, turn water supply on and off a few times.
Leave water supply off.

Replace END by engaging lugs and rotating 1/8 turn
clockwise.

Turn on water supply. Check that water level is at the marked
water line.

1/8

1/8

TO CONNECT WATER
SUPPLY

* Flexible hose (not provided) are
recommended to connect the supply
line to the fill valve. If you use a rigid
connection(not provided), take care
not to apply side forces to the bottom
of the fill valve. Be sure the rigid
connection must be fit with supply line
completely to prevent damage shank
by forced connection.

*

(

)

(

)

Supply Shank*

Supply Shut-Off Valve

Fig.#12

12

Install the tank lid and the seat. Use
the supplied hardware pack for seat.
Periodically check for leaks for several
days following the installation.

Fig.#13

13

-5-

1196288-T01-A

Summary of Contents for TRESHAM K-3854T

Page 1: ...rect roughing in dimension This toilet has a 305mm 400mm roughing in dimension Closet flange must be 305mm 400mm on center from wall Carefully inspect the new fixture for any sign of damage For new construction refer to the dimensions in for locating the shut off valve Fixture dimensions are nominal and conform to tolerances established by ASME Standards A112 19 2 2008 Handle vitreous china produc...

Page 2: ...e a supply shut off valve below the tank install one before installing the new toilet NOTICE 254mm 305mm 8mm T 2 10mm TO REMOVE EXISTING TOILET Turn off the water supply Flush the toilet and use a sponge to remove the remaining water from the tank and bowl Disconnect the supply shut off valve if present and remove the old tank and bowl Fig 1 1 INSTALLATION Unit mm 2 Kohler reserves the right to ch...

Page 3: ...damage caused by installation with the use of cement TO INSTALL SUPPLY SHUT OFF VALVE Install the supply shut off valve so it is 67mm 2 5 8 above the finished floor line and 194mm 7 5 8 to the left of the closet flange centerline The centerline of the supply shut off valve outlet should extend 67mm 2 5 8 from the finished wall Install the supply shut off valve with the outlet vertical Closet Flang...

Page 4: ...the toilet NOTE 1 NOTE 2 o Install plastic to ground and mounted with 3 set of bolts firmly Carefully align and lower the bowl Apply weight to the bowl rim to let the outlet insert into plastic trap Carefully thread the screws into the brackets until toilet is secure Alternately tighten left and right sides to prevent pulling the toilet off center Install cap to cover screw Do not overtighten 1 21...

Page 5: ...er supply off Replace END by engaging lugs and rotating 1 8 turn clockwise Turn on water supply Check that water level is at the marked water line 1 8 1 8 TO CONNECT WATER SUPPLY Flexible hose not provided are recommended to connect the supply line to the fill valve If you use a rigid connection not provided take care not to apply side forces to the bottom of the fill valve Be sure the rigid conne...

Page 6: ...e continues to run allowing water to enter tank 3 Incorrect water level height FILL FLOAT WITH BALLAST Adjust the float by the cross shaped thread and sliding it up or down on the float rod until the water level is at the marked water line Test flush the toilet Check all connections for leakage for several days Set the tank cover in place on the tank Fig 14 14 A Foreign particles lodged under the ...

Page 7: ...1 A B A B A B C D E A 1 8 1 8 B C D E 2 3 A B A B 4 A 2A A 5 A B C D A B C D 6 A B A B 7 1196288 T01 A ...

Page 8: ... cleaners or solvents Do not use in tank cleaners Products containing chlorine calcium hypochlorite can seriously damage fittings in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing chlorine calcium hypochlorite WARNING Risk of property or product damage 0 C o ...

Reviews: