4
113351-2-
AB
Kohler Co., Kohler, WI U.S.A.
3. TROUBLESHOOTING
To view the indicator you must remove the faceplate and
move the circuit board in the back until you can see the
LED lights.
GLOBAL URINAL–WITH COURTESY FLUSH
Cut the courtesy flush wire jumper (JP1) on the circuit
board. It is located on the circuit board as shown.
First 10 minutes from power up check:
The GREEN LED indicator is on constantly when
the urinal sensor detects an object.
A flush occurs 3 seconds after the urinal sensor de-
tects an object.
If the urinal sensor detects an object more than 1
minute, the GREEN LED flashes until the object is
removed. the urinal flushes once after the object
has been removed.
DOMESTIC URINAL–WITHOUT COURTESY
FLUSH
First 10 minutes from power up check:
The GREEN LED indicator is on constantly when
the urinal sensor detects an object.
If the urinal sensor detects an object more than 1
minute, the GREEN LED flashes until the object
is removed. The urinal flushes once after the
object has been removed.
BOTH TYPES OF URINALS
The Touchless battery urinal flush valve features
a low battery indicator-RED LED. The RED LED
indicator flashes when batteries need to be
replaced. Replace with C-cell alkaline batteries
only.
If the valve fails to operate, first check the low
battery indicator. If the indicator is not flashing,
check that water supply is on. If the valve still fails
to operate, replace the batteries.
Turn Counterclockwise
to Open Valve
GREEN LED
RED LED
JP1
In the U.S.A., call 1-800-4-KOHLER
In Mexico, call 001-877-680-1310
In Canada, call 1-800-964-5590
2001 Kohler Co.
113351-2-