3. Install the Rough Plumbing
NOTE:
Provide access to all plumbing connections to simplify further maintenance.
NOTE:
The drain line should be located before the unit is installed. The overflow and drain must be
installed in accordance with the manufacturer’s instructions. Locate the drain line and trap using the
dimensions given in the applicable diagram in the Roughing-In illustrations section.
Locate rough plumbing for the drain according to the rough-in dimensions.
NOTE:
If plumbing is to be installed on the unfinished stud wall, install the supplies after the module is
installed.
Position the plumbing according to the roughing-in information. Cap the supplies and check for
leaks.
Strap the supply connections to the stud framing.
If possible, provide an access at the back of the plumbing wall for servicing the supply and waste
piping.
Install the shower valving according to the manufacturer’s instructions. Do not install the trim at
this time.
Shower Elbow
Blocking
Shower Riser
Supply Valves
Blocking
Spout Elbow
78-1/2"
(199.4 cm)
Min.
Optional
24-1/4"
(61.6 cm)
Min.
Shower Elbow
Blocking
Shower Riser
Supply Valves
Blocking
Spout Elbow
76-1/2"
(194.3 cm)
Min.
Optional
22"
(55.9 cm)
Min.
17-1/4"
(43.8 cm)
8-3/4"
(22.2 cm)
Drain Cutout
Series 7110
with “Through the Floor” Drain
Series 7110
with “Above the Floor” Drain
Supply Lines
Supply Lines
Sterling
7
1021859-2-E