Troubleshooting (cont.)
Symptoms
Probable Causes
Recommended Action
3.
Whirlpool stops by itself.
A.
GFCI trips.
A.
Identify the source of fault and
correct it. If the problem persists,
refer to your installer or dealer.
B.
Suction blocked.
B.
Remove the obstruction.
C.
Jets are blocked.
C.
Remove the blockage.
D.
The motor has overheated and
protection device has activated.
D.
Check for blockage at the motor
vents. Remove blockage and allow
motor to cool. Check for suction
blockage. Remove the blockage and
allow motor to cool. Check for jet
blockage. Remove the blockage and
allow motor to cool.
4.
Whirlpool is noisy.
A.
The pump banding straps that
hold the pump to the bath have
not been cut.
A.
Cut the pump banding straps with
tin snips.
Sterling
7
1016905-5-K
Summary of Contents for Sterling 66051100
Page 30: ...1016905 5 K ...
Page 31: ...1016905 5 K ...