TO REMOVE EXISTING TOILET

Turn off the water supply. Flush the toilet, and use a sponge
to remove the remaining water from the tank and bowl.
Disconnect the supply shut-off valve (if present), and remove
the old tank and bowl.

(

)

INSTALLATION

K-5504T-TFC

Kohler reserves the right to change marked dimensions without prior notice.

Fig.#2

2

Remove the old gasket from the floor
and the closet flange with a putty knife.
Remove the old T-bolts and discard
them.

if the new toilet is not

installed immediately, temporarily stuff
a rag into the closet flange.

NOTICE:

T

NOTICE:

Do not use white cement or high lime content

cements to install this toilet. The expansion of cement due to
a rise in temperature may make the toilet crack or cause
damage. Kohler is not responsible for any damage caused by
installation with the use of cement.

Closet Flange

mm

67mm;

160mm
200

Fig.#3

3

TO INSTALL SUPPLY
SHUT-OFF VALVE

Install the supply shut-off valve so it is
160mm above the finished floor line,
and 200mm to the left of the closet
flange centerline.

The centerline of the supply shut-off
valve outlet should extend 67mm from
the finished wall. Install the supply
shut-off valve with the outlet vertical.

Supply Shut-Off Valve

Closet Flange
Centerline

200

305/400

160

400

FRONT OF BOWL

OF OUTLET

C

L

Finished Wall

717

387

685

489

265

373

655

1267611-T01-B

Supply

200

160

Summary of Contents for SAN MARTINE S-TRAP K-5503T-TFC

Page 1: ... 5503T TFC K 4713T 4 8 400mm K 5504T TFC K 4713T 1 1267611 T01 B NOTES Observe all local plumbing and building codes Shut off the water supply Seat post holes are on 140mm centers Ensure that the new drain has the correct roughing in dimension This toilet has a 305 400mm roughing in dimension Closet flange must be 305 400mm on center from wall Carefully inspect the new fixture for any sign of dama...

Page 2: ...ket wax seal Toilet T bolts 2 8mm 5 16 diameter Toilet supply shut off valve recommended If the existing toilet does not have a supply shut off valve below the tank install one before installing the new toilet NOTICE 20mm 1 2 254mm 305mm 8mm T 2 20mm Unit mm Reference Value K 5503T TFC FRONT OF BOWL OF OUTLET C L 305 Finished Wall 717 387 685 489 265 278 655 1267611 T01 B Supply 200 160 ...

Page 3: ... white cement or high lime content cements to install this toilet The expansion of cement due to a rise in temperature may make the toilet crack or cause damage Kohler is not responsible for any damage caused by installation with the use of cement Closet Flange mm 67mm 160mm 200 Fig 3 3 TO INSTALL SUPPLY SHUT OFF VALVE Install the supply shut off valve so it is 160mm above the finished floor line ...

Page 4: ...eratures less than 21 C If you are using a toilet gasket with an integral plastic sleeve make sure the gasket is positioned with the sleeve facing away from the toilet NOTE 1 NOTE 2 o 1 21 2 o C Install brackets Plastic Trap Outlet Toilet Gasket Fig 8 8 Install plastic to ground and mounted with 3 set of bolts firmly 3 NOTE Must use the toilet installation gasket ring not supplied to seal the area...

Page 5: ...st in supply line Supply Shank Supply Shut Off Valve Fig 12 12 IMPORTANT Make certain the top is turned to the locked position Valve may not turn on if top is not fully in the locked position Before turning on the supply valve for the first time follow the steps below to clear sand debris and rust from the system Make sure water sure water supply is off Remove valve END by rotating it 1 8 turn cou...

Page 6: ...flush the toilet Periodically check all connections for leaks for several days following installation Set the tank cover in place on the tank MINOR ADJUSTMENT OF WATER LEVEL Move the snap along OPEN direction OPEN To lower water level Move water cup down to a proper height and rotate screw anticlockwise to achieve the desired water level Refer to float adjustment instructions Screw Snap SCALE 5 1 ...

Page 7: ... surface E is 2 4mm lower than surface G Screw E Float Water Cup G To elevate water level Rotate screw clockwise and raise float to the desired water level Elevate water cup to a proper position as well Refer to float adjustment instructions Fig 15c 15c Fig 15d 15d Fig 15e 15e SCALE 5 1 OPEN CLOSE 1267611 T01 B ...

Page 8: ...ertighten If leakage continues replace the gasket E Adjust the tank water level if it is too high 2 No Flush IMPORTANT Use only genuine Kohler parts as shown to avoid property damage 4 Tank takes excessive time to fill 5 There is excessive noise when the tank is filling 3 The fill valve turns on off by itself without the toilet being flushed or it runs allowing water to enter the tank A Reconnect ...

Page 9: ...fittings in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing chlorine calcium hypochlorite WARNING Risk of property or product damage Please do not use hard materials like scouring pad to clean product surface especially the product logo CAUTION CAUTION Don t u...