background image

6

116627-2-

AC

Kohler Co., Kohler, WI

TROUBLESHOOTING CHART

SYMPTOMS

PROBABLE CAUSES

CORRECTIVE ACTION

1.  Float valve

turns on/off
by itself
without
toilet being
flushed.

A. Refill tube pushed too far down in overflow

pipe.

B. No slack in flapper chain assembly, holding

flapper off seat.

C. Flush valve flapper ball worn, dirty or

misaligned with flush valve seat; or seat
corroded so flapper will not seal.

A. Attach refill tube to overflow pipe above the

water line.

B. Adjust flapper chain assembly for proper slack.

C. Inspect, clean and, if necessary, replace flapper

ball and/or seat.

2.  Float valve

continues
to run,
allowing
water to
enter tank.

A. Foreign particles lodged under the float valve

seal (located under float valve cap).

B. Float valve seal (located under float valve cap)

may be cracked or split.

A. Shut off water supply; remove float valve cap

assembly by rotating 1/8 turn counterclockwise.
Cover uncapped lower valve unit with an
inverted cup (holding it to prevent overspray),
and turn water on and off a few times. Clean
float valve seal surface (located under float
valve cap). Replace float valve cap assembly by
engaging lugs and rotating 1/8 turn clockwise.
Turn water on.
Install filter in supply line to prevent recurring
problems.

B. Replace seal.

3.  Incorrect

water level
height.

A. Valve float cup does not contain enough water

to provide required ballast.

A. During fill cycle, hold float under water a few

seconds to allow it to fill with water ballast.

4.  Long or

noisy tank
fill cycle.

A. Plugged valve inlet or supply line.

A. Perform Corrective Action 2.A.

5.  Poor flush.

A. Trapway or rim holes are obstructed.
B. Soil pipe or vent is obstructed.
C. Low water level in bowl due to refill tube being

plugged or out of overflow tube.

D. Supply shut-off valve not fully open.

A. Unclog trapway; clean rim holes.
B. Clear obstruction from soil pipe or vent.
C. Clean or straighten refill tube; attach refill tube to

overflow tube.

D. Open supply shut-off valve.

6.  Toilet

overflows.

A. Toilet trapway is obstructed.
B. Soil pipe or vent is obstructed.

A. Use plunger to unclog.
B. Clear obstruction from soil pipe or vent pipe.

7.  Toilet does

not
activate.

A. Chain is not connected to lift rod or flush valve. A. Reconnect the chain.

Summary of Contents for REVIVAL

Page 1: ... codes Shut off the water supply Ensure that the new toilet has the correct roughing in dimension of 12 See Fig 3 Be very careful while working with vitreous china products Vitreous china can break or chip if the bolts and nuts are overtightened or if carelessly handled Carefully inspect the new fixture for any sign of damage Fixture dimensions are nominal and conform to tolerances established by ...

Page 2: ... If the new toilet is not installed immediately temporarily stuff a rag into the closet flange Fig 1 Closet Flange Install two new 5 16 diameter T bolts into the closet flange Fig 2 T Bolts Closet Flange TO INSTALL SUPPLY SHUT OFF VALVE Install the supply shut off valve so it is 9 above the finished floor line and 4 1 8 to the left of the closet flange centerline The centerline of the supply shut ...

Page 3: ...ble the bolt cap bases washers and nuts on the exposed T bolts Hand tighten the nuts then tighten them an additional 1 2 turn CAUTION Risk of personal injury or product damage Overtightening may cause breakage or chipping of the vitreous china If the T bolts extend more than 1 4 over the top of the nuts cut off the excess and file the end Wipe away any residue Install the bolt caps Fig 5 Nut Washe...

Page 4: ...the coupling nut and then tighten the compression nut Fig 7 Tubing Ferrule Supply Shank Seal Washer Coupling Nut Compression Nut Supply Shut Off Valve Compression Washer Tubing Coupling Nut Compression Nut Ferrule Open the supply shut off valve and check all connections for leakage If the connections have been properly assembled a slight retightening of the nuts should stop any leakage If the toil...

Page 5: ... China Tab Cover Bracket Carefully lift the front of the tank cover just enough to gain access to the flapper chain and lift rod Insert the flapper chain S hook into the middle hole in the lift rod Set the tank cover onto the tank Be sure the cover bracket and vitreous china tab are engaged Test flush the toilet several times to ensure proper operation If the flapper ball does not seat properly wh...

Page 6: ...ff a few times Clean float valve seal surface located under float valve cap Replace float valve cap assembly by engaging lugs and rotating 1 8 turn clockwise Turn water on Install filter in supply line to prevent recurring problems B Replace seal 3 Incorrect water level height A Valve float cup does not contain enough water to provide required ballast A During fill cycle hold float under water a f...

Page 7: ...ervice through either your contractor or Kohler Co distributor please write us directly at Kohler Co Attn Customer Service Department 444 Highland Drive Kohler WI 53044 USA or by calling 1 800 4 KOHLER from within the USA FOURTH Include all pertinent information regarding your claim including a complete description of the product model numbers colors finishes and the date the product was installed...

Page 8: ... 8 116627 2 AC Kohler Co Kohler WI ...

Reviews: