SYMPTOMS
CORRECTIVE ACTION
1. Poor Flush
A. Clean under the bowl rim.
B. Plunge the bowl, auger trap, and auger drain to clear blockage.
C. Adjust the gap between the actuator and plunger arm to approximately 1/8
(3 mm).
D. Fully open the supply stop.
E. Clean the screen with a medium to hard bristle brush. Replace the screen if necessary.
F. Refer to the installer/dealer for assistance.
A. Adjust gap between actuator and plunger arm to approximately 1/8
(3 mm).
B. Repair or replace plunger arm (refer to installer/dealer for assistance).
C. Replace the lower supply group.
2. No Flush
3. Bowl water continues to
flow or tank fill water
will not shut off.
A. Fully open the supply stop.
B. Tighten the nut. Turn the nut counterclockwise.
C. Hook the plunger arm over the trip arm.
D. Clean the screen. Retain the screen if necessary.
E. Replace the inlet components.
-8-
21
Install the tank lid and the seat. Use the supplied 1/4"-20 seat bolts
and washers. Periodically check for leaks for several days
following the installation.
1/4"-20
1.
A.
B.
C.
3mm
D.
E.
F.
/
A.
3mm
B.
/
C.
2.
3.
A.
B.
C.
D.
O
E.
1098366-T01-D