background image

1204812-T01-B

WARNING: Risk of personal injury or product
damage

WARNING: Risk of external leakage

: Handle vitreous china products very carefully.

Vitreous china can break and chip if you overtighten
bolts and nuts.

. The fill valve

nut has been factory-tightened to design specifications.
If re-tightening is required, wrench tighten one turn
past finger tight .

-2-

TOOLS AND MATERIALS REQUIRED (NOT
SUPPLIED)

·

·

·

·

·

·

·

·

·

254mm (10") adjustable wrench
305mm (12") pipe wrench
Tape measure
Level
Drill (10mm. Drill bit)
Screwdriver
Plastic connector (Supplied)
Toilet installation bolt (Supplied)
S-TRAP 1206391(Optional)/P-TRAP 1036901 (Supplied)

·
·
·
·
·
·
·
·
·

254
305

(

10mm)

(

)

(

)

S

1206391(

)/P

1036901(

)

ROUGHING-IN

Fig.#1

1

Kohler reserves the right to change marked dimensions without prior notice.

Finished Wall

Finished Wall

Finished Wall

Finished Wall

Reference Value

UNIT: mm

1036901
P-Trap

1206391
S-Trap(Optional)

(

)

185

90-110

550

C

C

L of Inlet

Inlet

L of Outlet

Outlet

380

352

185

85

215

358

350

155

Floor Fixings

55

102

Summary of Contents for PANACHE K-9154T

Page 1: ...ageway Ensure that the new drain has the correct roughing in dimension Carefully inspect the new fixture for any sign of damage For new construction refer to the dimensions in for locating the shut off valve Fig 1 Fixture dimensions are nominal and conform to tolerances established by ASME Standards A112 19 2 2013 The product complies with GB 6952 2015 51mm 1 ASME A112 19 2 2013 GB 6952 2015 ORDER...

Page 2: ...IRED NOT SUPPLIED 254mm 10 adjustable wrench 305mm 12 pipe wrench Tape measure Level Drill 10mm Drill bit Screwdriver Plastic connector Supplied Toilet installation bolt Supplied S TRAP 1206391 Optional P TRAP 1036901 Supplied 254 305 10mm S 1206391 P 1036901 ROUGHING IN Fig 1 1 Kohler reserves the right to change marked dimensions without prior notice Finished Wall Finished Wall Finished Wall Fin...

Page 3: ...ll as indicated on the template 4 Fit the clamps to the floor with the floor plugs washers and nuts 5 Position the bowl and install the soil pipe in accordance with the manufacturer s instructions An inlet isolating valve must be installed to the bowl 6 Connect the inlet water supply to the bowl 7 Secure the bowl in positon with the plastic sleeve and the screw Fit the plastic cover cap Note Cover...

Page 4: ...olvents Do not use in tank cleaners Products containing chlorine calcium hypochlorite can seriously damage fittings in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing chlorine calcium hypochlorite WARNING Risk of property or product damage WARNING Risk of prod...