background image

-3-

TO REMOVE EXISTING TOILET

Turn off the water supply. Flush the toilet, and use a sponge
to remove the remaining water from the tank and bowl.
Disconnect the supply shut-off valve (if present), and remove
the old tank and bowl.

(

)

Fig.#1

1

INSTALLATION

K-77740T-SL

Kohler reserves the right to change marked dimensions without prior notice.

Fig.#2

2

Remove the old gasket from the floor
and the closet flange with a putty knife.
Remove the old T-bolts and discard
them.

if the new toilet is not

installed immediately, temporarily stuff
a rag into the closet flange.

NOTICE:

T

NOTICE:

Do not use white cement or high lime content

cements to install this toilet. The expansion of cement due to
a rise in temperature may make the toilet crack or cause
damage. Kohler is not responsible for any damage caused by
installation with the use of cement.

Closet Flange

mm

67mm;

200mm
210

Fig.#3

3

TO INSTALL SUPPLY
SHUT-OFF VALVE

Install the supply shut-off valve so it is
200mm above the finished floor line,
and 160mm to the left of the closet
flange centerline.

The centerline of the supply shut-off
valve outlet should extend 67mm from
the finished wall. Install the supply
shut-off valve with the outlet vertical.

Supply Shut-Off Valve

Closet Flange
Centerline

210

305/400

200

OF OUTLET

C

L

400

FRONT OF BOWL

Finished Wall

Supply

200

210

365

700

390

422

737

380

1322807-T01-B

Summary of Contents for MODERN LIFE S-TRAP K-77739T-SL

Page 1: ...K 77380T MODERN LIFE Class Five One Piece Toilet 305mm K 77739T SL MODERN LIFE Class Five One Piece Toilet 400mm K 77740T SL 305mm K 77739T SL K 77380T 400mm K 77740T SL K 77380T NOTES Observe all local plumbing and building codes Shut off the water supply Seat post holes are on 140mm centers Ensure that the new drain has the correct roughing in dimension This toilet has a 305 400mm roughing in di...

Page 2: ... one before installing the new toilet NOTICE 254mm 305mm 10mm Unit mm Reference Value K 77739T SL FRONT OF BOWL OF OUTLET C L 305 Finished Wall Supply 200 210 WARNING Risk of personal injury or product damage WARNING Risk of external leakage Handle vitreous china products very carefully Vitreous china can break and chip if you overtighten bolts and nuts The fill valve nut has been factory tightene...

Page 3: ...ot use white cement or high lime content cements to install this toilet The expansion of cement due to a rise in temperature may make the toilet crack or cause damage Kohler is not responsible for any damage caused by installation with the use of cement Closet Flange mm 67mm 200mm 210 Fig 3 3 TO INSTALL SUPPLY SHUT OFF VALVE Install the supply shut off valve so it is 200mm above the finished floor...

Page 4: ... gasket should not be installed at temperatures less than 21 C If you are using a toilet gasket with an integral plastic sleeve make sure the gasket is positioned with the sleeve facing away from the toilet NOTE 1 NOTE 2 o 1 21 2 o C Install brackets Plastic Trap Outlet Toilet Gasket Fig 8 8 Install plastic to ground and mounted with 3 set of bolts firmly not supplied 3 NOTE Must use the toilet in...

Page 5: ...th the flared end last Slide the two inserts into the flared end of the hose guide Carefully thread the screws into the brackets until toilet is secure Alternately tighten left and right sides to prevent pulling the toilet off center Install cap to cover screw Do not overtighten Outlet Plastic Trap Cap Screw Bushing Fig 12 12 Apply caulk around base Hose Guide 1322807 T01 B ...

Page 6: ... side forces to the bottom of the fill valve Be sure the rigid connection must be fit with supply line completely to prevent damage shank by forced connection Supply Shank Supply Shut Off Valve Fig 13 13 IMPORTANT Make certain the top is turned to the locked position Valve may not turn on if top is not fully in the locked position Before turning on the supply valve for the first time follow the st...

Page 7: ...PORTANT Use only genuine Kohler parts as shown to avoid property damage 4 Tank takes excessive time to fill 5 There is excessive noise when the tank is filling 3 The fill valve turns on off by itself without the toilet being flushed or it runs allowing water to enter the tank A Reconnect the chain to the trip lever or flush valve B Adjust the chain assembly to remove excessive slack A Fully open t...

Page 8: ... This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing chlorine calcium hypochlorite WARNING Risk of property or product damage Please do not use hard materials like scouring pad to clean product surface especially the product logo CAUTION CAUTION Don t use any cement while ...

Reviews: