background image

-2-

Install the Basin

Note!

The lavatory tops must be installed on a cabinet or

matching metal stand (refer to Installation and User Guide
packed with the cabinet or stand for installation details).

Recommend Kohler metal square leg or Kohler bathroom
furniture for support or decoration.

!

(

)

!

·

76mm

·

Rough-in the supplies and the drain piping.

The supply stop handles cannot extend more than

76mm from the finish wall when in the open position.

NOTE:

Fig.#1

1

ROUGHING-IN DIMENSIONS

ROUGHING-IN DIMENSIONS

UNIT: mm

:

Kohler reserves the right to change marked dimensions without prior notice.

Reference Value

598

200

66

481

35

45

586

K-77835T-1

K-77835T-4

K-77835T-8

3- 35

592

356

481

598

200

66

Installation Side

80

181

102

3- 35

592

481

598

200

66

Installation Side

80

181

356

203

66

200

134

80

181

356

1269083-T01-B

Summary of Contents for MODERN LIFE K-77835T-1

Page 1: ...onform to tolerances established by ASME Standards A112 19 2 2013 The product complies with GB T 6952 2015 Make sure that the wall and floor are square and plumb to ensure proper installation IMPORTANT ASME A112 19 2 2013 GB T 6952 2015 ORDERING INFORMATION Modern Life 600mm Vanity K 77835T 1 4 8 600mm K 77835T 1 4 8 REQUIRED MATERIALS NOT SUPPLIED TOOLS Level Drill with bit 6mm 14mm wrench Framin...

Page 2: ...the supplies and the drain piping The supply stop handles cannot extend more than 76mm from the finish wall when in the open position NOTE Fig 1 1 ROUGHING IN DIMENSIONS ROUGHING IN DIMENSIONS UNIT mm Kohler reserves the right to change marked dimensions without prior notice Reference Value 598 200 66 481 35 45 586 K 77835T 1 K 77835T 4 K 77835T 8 3 35 592 356 481 598 200 66 Installation Side 80 1...

Page 3: ...l attached surface of the lav evenly Apply Silicone sealant along this face Washer Nut Offset Nut Fig 3 3 10mm 65 75mm 1 2 3 2 Drill two 10mm hanger bolt holes at the marks on the wall The nylon anchors is needed for concrete wall supplied Mount hanger bolts to the wall so approximately 65 75mm of each bolt remains exposed 1 Height dimensions marked in fig 2 and fig 3 could be adjusted per your th...

Page 4: ...verflow pipes shall be fixed onto the outlet valve Fix the overflow head assembly vertically onto the faucet supply pipe with plastic tie as shown in Fig 4 The overflow pipes can be fixed on either the right side or the left side of the supply pipe and shall not interfere with the lift rod The height of the overflow head assembly will affect the overflow level and can be adjusted if necessary plea...

Reviews: