11
Three case inserts are supplied with the Mira Escape, so that they can be trimmed
to suit the supplies entering the product. Before ¿tting the cover, make sure that
the case inserts are ¿tted.
Thoroughly Àush the mains-fed cold water supply pipe. The supply must
be clean and free from debris BEFORE connecting the Mira Escape.
To Àush the pipework, turn on the water supply and drain a minimum of 10 litres
(2 gallons) of water into a bucket or catchment area. Turn off the water supply.
An installation template is supplied to help you install the Mira Escape.
Put the installation template on the wall and mark through the positions of the
¿xing holes. Make sure that the position of these holes do not come in line with
any buried cables or pipework. Make sure that suf¿cient electrical supply cable
is available for connection to the terminal block.
Drill and plug the top two ¿xing holes. Secure the Mira Escape to the wall
with appropriate screws. Drill the bottom ¿xing hole with the product in place.
Alternative ¿xings (not supplied) may be necessary for some wall structures.
Avoid drilling into any supply cable/pipe.
Install the mains-fed cold water supply
pipe. Do not overtighten.
Feed cable into Case. Fit Earth sleeve
(not supplied) and strip insulation.
Do not twist cable cores.
Important! Make sure
that the inlet earth wire is
routed as shown. Failure
to do so may cause
product malfunction.