7
1333238-W2-A
Specification
•
Max Static Pressure:
10 Bar
.
•
Max Maintained Pressure:
5 Bar
.
•
Min Maintained Pressure: (Gas Water Heater):
1.0 Bar
(for
optimum performance supplies should be nominally equal).
•
Min Maintained Pressure (Gravity System):
0.1 Bar
(0.1 bar =
1 Metre head from cold tank base to shower handset outlet).
Pressures
•
Close temperature control is provided between
20°C and 50°C
.
•
Optimum Thermostatic Control Range:
35°C to 45°C
(achieved
with supplies of 15°C cold, 65°C hot and nominally equal
pressures).
•
Recommended Hot Supply:
60°C to 65°C
(
Note!
The mixing
valve can operate at temperatures up to 85°C for short periods
without damage. However for safety reasons it is recommended
that the maximum hot water temperature is limited to 65°C).
•
Minimum Recommended Differential between Hot Supply and
Outlet Temperature:
12°C at desired flow rates
.
•
Minimum hot water supply temperature:
55°C
.
Temperatures
•
For safety and comfort the thermostat will shut off the mixing
valve
within 2 Seconds
if either supply fails (achieved only if
the blend temperature has a minimum differential of 12°C from
either supply temperature).
Thermostatic Shut-down
Connections
•
Hot: Left
- 15mm pipework, 3/4” BSP to valve.
•
Cold: Right
- 15mm to pipework, 3/4” BSP to valve.
•
Outlet: Bottom
- 1/2” BSP Male to flexible hose.
Note!
This product does not allow for reversed inlets and will
deliver unstable temperatures if fitted incorrectly.