9
OPERATION
The
Mira Bijou
and
Mira Ordo
are thermostatic
mixing valves which have a single sequential
control knob for on/off and temperature control.
The control knob operates anti-clockwise in the
following sequence:
•
Off
•
On
•
Cold
•
Warm
•
Maximum Preset Temperature
Maximum Preset
Temperature
Off
COMMISSIONING
Maximum Temperature Setting
Before using the shower the maximum temperature
must be checked to make sure that it is at a safe
level. It has been preset to approximately 41°C at
the factory but due to variations in site conditions
the maximum temperature may need adjustment.
Note!
Make sure that the hot water temperature
is at least 55°C and that there is sufficient supply.
For Type 2 installations the maximum blend
temperature is determined by the application,
refer to he TMV2 Requirements Manual.
1.
Turn on the mixer to the maximum temperature
and maximum flow (i.e. fully anticlockwise) and
allow the temperature to stabilise.
If the temperature is too hot or too cold adjust
as follows:
5.
Insert the 2.5 mm hexagon key into the centre
of the spindle and engage with the recessed
temperature adjusting screw.
6.
Rotate the hexagon key until the required
maximum temperature is obtained at the
shower. Rotate anticlockwise to increase the
temperature, or clockwise to decrease the
temperature (¼ turn = approximately 1°C).
7.
Once the desired maximum blend temperature
has been achieved turn off the mixer by
rotating the hub fully clockwise.
Note!
Do not remove the
hub.
8.
Refit the hub retaining screw.
9.
Refit the control knob with the grubscrew at
the bottom and retighten the grubscrew.
10.
Refit the concealing cap.
11.
Check that the shower temperature is correct.
Control Knob
Hub
Hub Retaining
Screw
Grubscrew
+
-
Concealing Cap
2.5 mm Hexagonal Key
2.
Carefully remove the concealing cap from the
control knob.
3.
Loosen the control knob grubscrew with the
2.5 mm hexagon key (supplied) and pull off
the control knob.
4.
Unscrew the hub retaining screw with a
2.5 mm hexagon key.
Note!
Do not remove the
hub.