background image

9

OPERATION

The

 Mira Bijou

 and 

Mira Ordo 

are thermostatic 

mixing valves which have a single sequential 

control knob for on/off and temperature control.
The control knob operates anti-clockwise in the 

following sequence:

• 

Off

• 

On

• 

Cold

• 

Warm

• 

Maximum Preset Temperature

Maximum Preset 

Temperature

Off

COMMISSIONING

Maximum Temperature Setting

Before using the shower the maximum temperature 

must be checked to make sure that it is at a safe 

level. It has been preset to approximately 41°C at 

the factory but due to variations in site conditions 

the maximum temperature may need adjustment. 

Note!

 Make sure that the hot water temperature 

is at least 55°C and that there is sufficient supply. 

For Type 2 installations the maximum blend 

temperature is determined by the application, 

refer to he TMV2 Requirements Manual.

1. 

Turn on the mixer to the maximum temperature 

and maximum flow (i.e. fully anticlockwise) and 

allow the temperature to stabilise.

  If the temperature is too hot or too cold adjust 

as follows:

5.

  Insert the 2.5 mm hexagon key into the centre 

of the spindle and engage with the recessed 

temperature adjusting screw.

6. 

Rotate the hexagon key until the required 

maximum temperature is obtained at the 

shower. Rotate anticlockwise to increase the 

temperature, or clockwise to decrease the 

temperature (¼ turn = approximately 1°C).

7.

  Once the desired maximum blend temperature 

has been achieved turn off the mixer by 

rotating the hub fully clockwise.

 

Note! 

Do not remove the

 

hub.

8.

  Refit the hub retaining screw.

9. 

Refit the control knob with the grubscrew at 

the bottom and retighten the grubscrew.

10. 

Refit the concealing cap.

11. 

Check that the shower temperature is correct.

Control Knob

Hub

Hub Retaining 

Screw

Grubscrew

+

-

Concealing Cap

2.5 mm Hexagonal Key

2.

  Carefully remove the concealing cap from the 

control knob.

3.

  Loosen the control knob grubscrew with the 

2.5 mm hexagon key (supplied) and pull off 

the control knob.

4.

  Unscrew the hub retaining screw with a 

2.5 mm hexagon key.

 

Note! 

Do not remove the

 

hub.

Summary of Contents for mira Bijou

Page 1: ...1 Mira Bijou and Mira Ordo Thermostatic Mixers These instructions must be left with the user Installation and User Guide For SPARES ADVICE or REPAIRS Please call us on 0844 571 5000 UK Only...

Page 2: ...response to changes in pressures or temperature of the incoming water supplies to maintain the selected temperature An adjustable maximum temperature stop is provided which limits the temperature to a...

Page 3: ...ed the end of its serviceable life it should be disposed of in a safe manner in accordance with current local authority recycling or waste disposal policy PACK CONTENTS Tick the appropriate boxes to f...

Page 4: ...nd nominally equal pressures Recommended Hot Supply 60 C to 65 C Note The mixing valve can operate at higher temperatures for short periods without damage however this could detrimentally affect therm...

Page 5: ...ter Supply Regulations 1999 Water Fittings or any particular regulations and practices specified by the local water company or water undertakers Note Make sure that all site requirements correspond to...

Page 6: ...u are retro fitting your mixing valve onto existing pipework an Adjustable Elbow Pack is available if required refer to section Accessories 39 mm 3 For solid walls drill the holes for the backplate wi...

Page 7: ...0 g The control knob will have to be realigned i e removed and turned through 180 this can be completed after commissioning Plug Cap Sealing Plug O Seal Outlet Nipple Grubscrew 7 Remove the backplate...

Page 8: ...he spacer and shelf onto the mixer Use a spirit level to make sure that the shelf is level and tighten the fixing bolt using a 4 mm hexagonal key supplied Caution Do not overtighten Fixing Bolt Spacer...

Page 9: ...allow the temperature to stabilise If the temperature is too hot or too cold adjust as follows 5 Insert the 2 5 mm hexagon key into the centre of the spindle and engage with the recessed temperature a...

Page 10: ...er leaking from showerhead Cause Rectification Normal for a short period after shut off Check that the pressures are not in excess of the specifications for the product Renew the thermostatic cartridg...

Page 11: ...shelf components identified D 1663 168 Pipe Concealing Plates x2 1663 154 Elbow Connector Assembly 1663 158 Outlet Nipple 1663 160 Outlet Plug 1663 231 Elbow Assembly 1663 157 Backplate Assembly 1663...

Page 12: ...any kind Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed representative Routine maintenance or replacement parts to comply with the re...