7
6. Reversed Inlet Supplies Only:
a)
Using a suitable tool, carefully remove the
plug cap from the centre of the sealing
plug to reveal keyway.
b)
Remove the sealing plug using the ‘O’ key
(supplied) or a 12 mm hexagonal key.
c)
Remove the outlet nipple using the ‘O’ key
(supplied) or a 12 mm hexagonal key.
d)
Refit the sealing plug and outlet nipple in
the opposite outlets and tighten.
Note!
Make sure that the ‘O’ seals are
correctly fitted.
e)
Remove the grubscrew using a 3 mm
hexagonal key (not supplied) and fit in
the opposite side of the mixer body.
f)
Rotate the mixer 180°.
g)
The control knob will have to be realigned,
i.e. removed and turned through 180°, this
can be completed after commissioning.
Plug Cap
Sealing Plug
‘O’ Seal
Outlet Nipple
Grubscrew
7.
Remove the backplate from the mixer by
loosening the grubscrew with a 2.5 mm
hexagonal key (supplied).
8.
Secure the backplate to the wall using the
screws (supplied).
Screw
Backplate
9. For Rear Entry Supplies Only:
a)
Fit the concealing plates over the inlet
pipes.
Note!
Apply silicone sealant to the back
face of the flange.
Apply Silicone Sealant
Concealing Plate
10. Caution! It is essential at this point
that the supply pipework is thoroughly
flushed through before connection to the
mixer.
Failure to do so may result in product
malfunction and will not be covered under the
guarantee.