3
112766–2–
AA
(0993)
Kohler Co., Kohler, WI
SERVICE PROCEDURES
If cause of problem is unknown, see troubleshooting chart
first. Then refer to procedure by component assembly
subheading.
Use clean strap wrench to remove showerhead from
shower arm. Blow water out of showerhead with air.
For any flow/performance problem, the first item to check
is the inlet screen and flow control located in the ball joint.
BALL JOINT ASSEMBLY
Gently pry up edge of the inlet screen using thin-bladed
screwdriver.
Remove and clean screen. With screen removed, visually
inspect the three orifice holes in the flow control.
If holes in flow control require cleaning, use a toothpick or
similar thin, pointed tool to clean the three holes.
NOTE: The flow control is press fit into place and cannot
be removed.
Fig. #5
Ball Joint
Screen
Ball Joint
Orifice Holes
Flow Control
AERATOR HOUSING
(THREE-WAY MODELS ONLY)
Using the special tool provided, insert prongs into aerator
housing holes on face of showerhead. Turn tool
counterclockwise to remove aerator housing.
Fig. #6
Showerhead
Showerhead Tool
Remove rubber gasket and aerator plate. Turn housing
over, letting aerator fall out. Clean both sides of aerator.
Replace aerator into aerator housing, aligning notch in
aerator with keyway in aerator housing.
Replace aerator plate with small diameter ring facing up.
Replace gasket. Unless proceeding to front housing
assembly service, replace assembly into showerhead. Do
not overtighten.
Fig. #7
Aerator Housing
Aerator Plate
Gasket
Aerator